Product type: ESB16-20N-07
Installationsschütz 16 A, 2S/0Ö, 400 V AC/DC
Description
| Thomas Hoffmann |
| +49 305 201 4443 |
| sales@zwodltd.com |
| Price: Please send request |
| Request Lead Time: app. 1 Day |
| Delivery Time: app. 4-5 Weeks Estimated delivery time to our warehouse in Berlin |
| Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2025 |
| Product Attribute | Attribute Value |
|---|---|
| Weight | 0.14 KG / psc. |
| Commodity number | 85365080 |
| Country of origin | BG |
| Dimensions (WxHxD) | 0.018x0.085x0.065 m |
| EAN code | 3471523007192 |
| Product group | AQ |
| eclass | V11.0 : 27142308 |
| etim 5 | EC001653 - Installation contactor for distribution board |
| etim 6 | EC001653 - Installation contactor for distribution board |
| etim 7 | EC001653 - Installation contactor for distribution board |
| etim 8 | EC001653 - Installation contactor for distribution board |
| unspsc | 39121529 |
| standards | IEC/EN 60947-1IEC/EN 60947-4-1UL 60947-1UL 60947-4-1IEC/EN 61095 |
| rohs status | Following EU Directive 2011/65/EU |
| cb certificate | https://library.abb.com/d/1SAA920007-2001 |
| nf certificate | https://library.abb.com/d/1SAA920002-1201 |
| abs certificate | https://library.abb.com/d/1SAA920000-0101 |
| cqc certificate | https://library.abb.com/d/CQC2018010304057353, https://library.abb.com/d/CQC2018010304057344 |
| dnv certificate | https://library.abb.com/d/1SAA920000-0306 |
| eac certificate | https://library.abb.com/d/1SAA920003-2701 |
| number of poles | 2 |
| pollution degree | 3 |
| rmrs certificate | https://library.abb.com/d/1SAA920000-0705 |
| rohs information | https://library.abb.com/d/1SAD938506-0302 |
| culus certificate | https://library.abb.com/d/cUL_E191658 |
| dimension diagram | https://library.abb.com/d/1SBB505186D3001 |
| tightening torque | Control Circuit 0.9 N·mMain Circuit 1.2 N·m |
| rated frequency (f) | Control Circuit DCControl Circuit 50 HzControl Circuit 60 HzControl Circuit 400 HzMain Circuit DCMain Circuit 50 HzMain Circuit 60 Hz |
| degree of protection | IP20 |
| electrical durability | AC-1 (NO) 150000 cycleAC-3 (NO) 150000 cycleAC-7a (NO) 150000 cycleAC-7b (NO) 150000 cycle |
| mechanical durability | 1000000 cycle |
| wire stripping length | Control Circuit 7 mmMain Circuit 10 mm |
| ambient air temperature | Operation -25 ... +55 °CStorage -40 ... +80 °C |
| horsepower rating ul/csa | (220 ... 240 V AC) Single Phase, NO 0.75 Hp |
| recommended screw driver | Control Circuit Pozidriv 1Main Circuit Pozidriv 1 |
| tightening torque ul/csa | Control Circuit 8 in·lbMain Circuit 11 in·lb |
| environmental information | https://library.abb.com/d/1SAC200061H0009 |
| rated operational voltage | Main Circuit 220 V DCMain Circuit 250 V AC |
| number of main contacts nc | 0 |
| number of main contacts no | 2 |
| object classification code | Q |
| rated insulation voltage (ui) | 400 V |
| declaration of conformity - ce | https://library.abb.com/d/1SAD938506-0302 |
| declaration of conformity - ccc | https://library.abb.com/d/2020980304001370, https://library.abb.com/d/2020980304001371 |
| number of auxiliary contacts nc | 0 |
| number of auxiliary contacts no | 0 |
| connecting capacity main circuit | Flexible with Ferrule 1x 1 ... 6 mm2Flexible with Ferrule 2x 1 ... 2.5 mm2Flexible with Insulated Ferrule 1x 1 ... 6 mm2Flexible with Insulated Ferrule 2x 1 ... 1.5 mm2Flexible 1x 1 ... 6 mm2Flexible 2x 1 ... 4 mm2Rigid 1x 1 ... 10 mm2Rigid 2x 1 ... 4 mm2 |
| declaration of conformity - ukca | https://library.abb.com/d/1SAD938501-1302 |
| maximum operating voltage ul/csa | Main Circuit 240 V AC |
| rated operational power ac-1 (pe) | (230 V) Single Phase, NO 3.7 kW |
| rated operational power ac-3 (pe) | (230 V) Single Phase, NO 0.9 kW |
| idea granular category code (igcc) | 4759 >> Installation contactor for distribution board |
| rated control circuit voltage (uc) | 400 V |
| rated operational power ac-7a (pe) | (230 V) Single Phase, NO 3.7 kW |
| rated operational power ac-7b (pe) | (230 V) Single Phase, NO 0.9 kW |
| connecting capacity control circuit | Flexible with Ferrule 1x 1 ... 2.5 mm2Flexible with Ferrule 2x 0.75 ... 1.5 mm2Flexible with Insulated Ferrule 1x 1 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 1 mm2Flexible 1x 1 ... 2.5 mm2Flexible 2x 1 ... 1.5 mm2Rigid 1x 0.5 ... 4 mm2Rigid 2x 0.75 ... 2.5 mm2 |
| rated operational current ac-1 (ie) | (NO) 16 A |
| rated operational current ac-3 (ie) | (230 V) Single Phase, NO 6 A |
| width in number of modular spacings | 1 |
| rated operational current ac-7a (ie) | (NO) 16 A |
| rated operational current ac-7b (ie) | (230 V) Single Phase, NO 6 A |
| maximum operating altitude permissible | 2000 m |
| rated impulse withstand voltage (uimp) | 6 kV |
| connecting capacity main circuit ul/csa | Solid 14-8 AWGStranded 14-8 AWG |
| connecting capacity control circuit ul/csa | Solid 16-10 AWGStranded 16-10 AWG |
| resistance to shock acc. to iec 60068-2-27 | 11 ms Pulse 15g |