ABB

1SBH101004R2631

Product type: NS31ES-26

NS31ES-26 230V50/60HZ Contactor Relay

RoHS Compliant

Description

NS... contactor relays are used for switching auxiliary circuits and control circuits. The NS..S contactor relays are the spring terminal version of the NS... range. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. NS31ES-26
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • NS Contactor Relays
  • NS
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 40
Product Specifications
Product AttributeAttribute Value
Weight0.22 KG / psc.
Commodity number85364900
Country of originCN
Dimensions (WxHxD)78x48x80 mm
EAN code3471523009264
Product groupSB
eclass V11.1 : 27371001
etim 4 EC000196 - Contactor relay
etim 5 EC000196 - Contactor relay
etim 6 EC000196 - Contactor relay
etim 7 EC000196 - Contactor relay
etim 8 EC000196 - Contactor relay
unspsc 39121529
standards IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
rohs status Following EU Directive 2002/95/EC August 18, 2005 and amendment
operate time Between Coil De-energization and NC Contact Closing 7 ... 22 msBetween Coil De-energization and NO Contact Opening 5 ... 19 msBetween Coil Energization and NC Contact Opening 6 ... 18 msBetween Coil Energization and NO Contact Closing 9 ... 24 ms
terminal type Spring Terminals
cb certificate https://library.abb.com/d/CB_CN_32453
ul certificate https://library.abb.com/d/UL_220108-E312527A
ccc certificate https://library.abb.com/d/CCC_2007010305248106
cqc certificate https://library.abb.com/d/CQC2007010305248106
gost certificate https://library.abb.com/d/GOST_POCCCNME77B07821.pdf
rohs information https://library.abb.com/d/1SBD251007E1000
climatic withstand Category B according to IEC 60947-1 Annex Q
rated frequency (f) Auxiliary Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
wire stripping length Auxiliary Circuit 10 mmControl Circuit 10 mm
ambient air temperature Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
environmental information https://library.abb.com/d/1SBD250159E1000
rated operational voltage Auxiliary Circuit 690 VMain Circuit 690 V
object classification code K
rated insulation voltage (ui) acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SBD250016U1000
declaration of conformity - ccc https://library.abb.com/d/2020980304001219
number of auxiliary contacts nc 1
number of auxiliary contacts no 3
declaration of conformity - ukca https://library.abb.com/d/1SBD250051U1000
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) 50 Hz 230 V60 Hz 230 V
connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
rated operational current ac-15 (ie) (500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
rated operational current dc-13 (ie) (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W
connecting capacity auxiliary circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
maximum electrical switching frequency (AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour
maximum mechanical switching frequency 3600 cycles per hour
maximum operating altitude permissible 3000 m
rated impulse withstand voltage (uimp) Auxiliary Circuit 6 kV
resistance to shock acc. to iec 60068-2-27 Closed, Shock Direction: C1 19 gClosed, Shock Direction: C2 16 gOpen, Shock Direction: C1 8 gOpen, Shock Direction: C2 13 gShock Direction: A 20 gShock Direction: B1 5 gShock Direction: B2 15 g
conventional free-air thermal current (ith) acc. to IEC 60947-5-1, q = 40 °C 10 A
resistance to vibrations acc. to iec 60068-2-6 5 ... 300 Hz 3 g Closed position / 2 g Open position
rated short-time withstand current low voltage (icw) for 0.1 s 140 Afor 1 s 100 A