ABB

1SBH137061R1440

Product type: NFB40E-14

NFB40E-14 250-500V50/60HZ-DC Contactor

RoHS Compliant

Description

The NFB40E-14 is a contactor relay complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. It is used for switching auxiliary and control circuits. These contactor relays: • include screw terminals for connection with standard ferrules for a safe insertion and wiring of cables. • improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C • meet all main general and rolling stocks standards: IEC 60947-5-1 and the shocks and vibration withstand conforming to IEC 61373 cat. 1, class B • reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting • reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation • get an electronic coil interface accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data) • include a wide range of auxiliary contact blocks for front and side mounting. NFB40E-14
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • NF Contactor Relays
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.31 KG / psc.
Commodity number85364900
Country of originFR
Dimensions (WxHxD)87x47x79 mm
EAN code3471523104846
Product groupSR
eclass V11.0 : 27371003
etim 4 EC000196 - Contactor relay
etim 5 EC000196 - Contactor relay
etim 6 EC000196 - Contactor relay
etim 7 EC000196 - Contactor relay
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121500
standards IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
rohs status Following EU Directive 2011/65/EU
operate time Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
terminal type Screw Terminals
cb certificate https://library.abb.com/d/CB_SE-93051M2
ul certificate https://library.abb.com/d/UL_20130206-E252354-2-1
ccc certificate https://library.abb.com/d/CCC_2011010303465426
cqc certificate https://library.abb.com/d/CQC2019010303267993
cul certificate https://library.abb.com/d/UL_20180227_E252354_2_1
eac certificate https://library.abb.com/d/EAC_RU C-FR ME77 B01006
ul listing card https://library.abb.com/d/UL_E252354
gost certificate https://library.abb.com/d/GOST_POCCFR.ME77.B06804.pdf
rmrs certificate https://library.abb.com/d/RMRS_1802702280
rohs information https://library.abb.com/d/1SBD250006U1000
climatic withstand Category B according to IEC 60947-1 Annex Q
rated frequency (f) Main Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
mounting on din rail TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
ambient air temperature Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
environmental information https://library.abb.com/d/1SBD250167E1000, https://library.abb.com/d/1SBC100222M0201
rated operational voltage Auxiliary Circuit 690 V
object classification code K
rated insulation voltage (ui) acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SBD250006U1000
declaration of conformity - ccc https://library.abb.com/d/2020980303000175
number of auxiliary contacts nc 0
number of auxiliary contacts no 4
declaration of conformity - ukca https://library.abb.com/d/1SBD250037U1000
mounting by screws (not supplied) 2 x M4 screws placed diagonally
rated control circuit voltage (uc) 50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V
rated operational current ac-15 (ie) (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
rated operational current dc-13 (ie) (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
maximum electrical switching frequency (AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour
maximum mechanical switching frequency 6000 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) 6 kV
conventional free-air thermal current (ith) acc. to IEC 60947-5-1, q = 40 °C 16 A
rated short-time withstand current low voltage (icw) for 0.1 s 140 Afor 1 s 100 A