ABB

1SBL113004R8101

Product type: ASL12-30-01S-81

ASL12-30-01S-81 24VDC Contactor

RoHS Compliant

Description

ASL12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs. ASL12-30-01S-81
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • AS Contactors
  • ASL12
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 40
Product Specifications
Product AttributeAttribute Value
Weight0.28 KG / psc.
Commodity number85364900
Country of originCN
Dimensions (WxHxD)78x48x80 mm
EAN code3471523060111
Product groupSB
eclass V11.1 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
operate time Between Coil De-energization and NC Contact Closing 15 ... 20 msBetween Coil De-energization and NO Contact Opening 13 ... 17 msBetween Coil Energization and NC Contact Opening 31 ... 53 msBetween Coil Energization and NO Contact Closing 36 ... 59 ms
terminal type Spring Terminals
cb certificate https://library.abb.com/d/CB_CN13475-M1
ul certificate https://library.abb.com/d/UL_20120917-E312527-1-1
ccc certificate https://library.abb.com/d/CCC_2007010309251577
cqc certificate https://library.abb.com/d/CQC2007010309251577
ul listing card https://library.abb.com/d/UL_E312527
gost certificate https://library.abb.com/d/GOST_POCCCNME77B07822.pdf
rohs information https://library.abb.com/d/1SBD251006E1001
climatic withstand Category B according to IEC 60947-1 Annex Q
rated frequency (f) Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20IP20
wire stripping length Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 10 mm
ambient air temperature Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
horsepower rating ul/csa (120 V AC) Single Phase 1/2 hp(200 ... 208 V AC) Three Phase 2 hp(220 ... 240 V AC) Three Phase 3 hp(240 V AC) Single Phase 1.5 hp(440 ... 480 V AC) Three Phase 7.5 hp(550 ... 600 V AC) Three Phase 10 hp
environmental information https://library.abb.com/d/1SBD250157E1000
general use rating ul/csa (600 V AC) 12 A
maximum breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
rated operational voltage Auxiliary Circuit 690 VMain Circuit 690 V
number of main contacts nc 0
number of main contacts no 3
object classification code Q
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SBD250014U1000
declaration of conformity - ccc https://library.abb.com/d/2020980304001224
number of auxiliary contacts nc 1
number of auxiliary contacts no 0
connecting capacity main circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
declaration of conformity - ukca https://library.abb.com/d/1SBD250049U1000
rated operational power ac-3 (pe) (400 V) 5.5 kW(415 V) 5.5 kW(440 V) 5.5 kW(500 V) 5.5 kW(690 V) 5.5 kW(220 / 230 / 240 V) 3 kW
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) DC Operation 24 V
connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
rated operational current ac-1 (ie) (690 V) 40 °C 22 A(690 V) 60 °C 17 A(690 V) 70 °C 14 A
rated operational current ac-3 (ie) (415 V) 60 °C 12 A(440 V) 60 °C 11 A(500 V) 60 °C 11 A(690 V) 60 °C 7 A(380 / 400 V) 60 °C 12 A(220 / 230 / 240 V) 60 °C 12 A
rated operational current ac-15 (ie) (500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
rated operational current dc-13 (ie) (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W
connecting capacity auxiliary circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
maximum electrical switching frequency (AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
maximum mechanical switching frequency 3600 cycles per hour
maximum operating altitude permissible 3000 m
rated impulse withstand voltage (uimp) Auxiliary Circuit 6 kV
resistance to shock acc. to iec 60068-2-27 Closed, Shock Direction: B1 10 gClosed, Shock Direction: C1 20 gClosed, Shock Direction: C2 20 gOpen, Shock Direction: B1 5 gOpen, Shock Direction: C1 9 gOpen, Shock Direction: C2 14 gShock Direction: A 20 gShock Direction: B2 15 g
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 22 Aacc. to IEC 60947-5-1, q = 40 °C 10 A
resistance to vibrations acc. to iec 60068-2-6 5 ... 300 Hz 3 g Closed position / 2 g Open position
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 Afor 0.1 s 140 Afor 1 s 100 A
We’re sorry, our website no longer supports