ABB

1SBL281022R8010

Product type: UA30-30-10 220-230V 50Hz / 230-240V 60Hz

UA30-30-10 220-230V 50Hz / 230-240V 60Hz Contactor

Description

UA30 3-pole contactors for capacitor switching, can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the contactor. It also specifies the maximum peak current Î values accepted by the contactor. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. In these conditions, electrical durability of contactors is equal to 100 000 operating cycles. The UA.. series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • UA and UA..RA Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 4-5 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.71 KG / psc.
Commodity number85364900
Country of originBG
Dimensions (WxHxD)54x90x108.3 mm
EAN code3471522074805
Product groupSB
eclass V11.0 : 27371006
etim 4 EC001079 - Capacitor magnet contactor
etim 5 EC001079 - Capacitor magnet contactor
etim 6 EC001079 - Capacitor contactor
etim 7 EC001079 - Capacitor contactor
etim 8 EC001079 - Capacitor contactor
unspsc 39121529
rohs status Following EU Directive 2011/65/EU
operate time Between Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NO Contact Closing 8 ... 21 ms
terminal type Screw Terminals
cb certificate https://library.abb.com/d/CB_FR2880_60002378
ul certificate https://library.abb.com/d/UL_071301E39231
ccc certificate https://library.abb.com/d/CCC_2003010304060095
cqc certificate https://library.abb.com/d/CQC2003010304060095, https://library.abb.com/d/CQC2007010309256050
csa certificate https://library.abb.com/d/CSA_1033838_LR056745
coil consumption Average Holding Value 50 / 60 Hz 12 V·AAverage Pull-in Value 50 Hz 120 V·AAverage Pull-in Value 60 Hz 120 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 3 WHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
gost certificate https://library.abb.com/d/GOST_POCCFRME77B07175
rohs information https://library.abb.com/d/1SBD250805U1000
climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
e-number (finland) 3709173
rated frequency (f) Supply Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
mounting on din rail TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
mechanical durability 10 million
ambient air temperature Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... 55 °CNear Contactor for Operation in Free Air (Uc) -40 ... 70 °C
environmental information https://library.abb.com/d/1SBD250028E1000
maximum breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
rated operational voltage Auxiliary Circuit 690 VMain Circuit 690 V
number of main contacts nc 0
number of main contacts no 3
object classification code Q
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SBD250805U1000
declaration of conformity - ccc https://library.abb.com/d/2020980304001610, https://library.abb.com/d/2020980304001216
number of auxiliary contacts nc 0
number of auxiliary contacts no 1
connecting capacity main circuit Flexible with Cable End 2.5 ... 10 mm2Rigid Cable 2.5 ... 16 mm2
declaration of conformity - ukca https://library.abb.com/d/1SBD250822U1000
short-circuit protective devices Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 1.5 ... 1.8 A
data sheet, technical information https://library.abb.com/d/1SBC101140C0203
mounting by screws (not supplied) 2 x M4 screws placed diagonally
rated control circuit voltage (uc) 50 Hz 220 ... 230 V60 Hz 230 ... 240 V
rated operational power ac-6b (pe) (230 / 240 V) 40 °C, 50 / 60 Hz 16 kvar(230 / 240 V) 55 °C, 50 / 60 Hz 16 kvar(230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar(400 / 415 V) 40 °C, 50 / 60 Hz 27.5 kvar(400 / 415 V) 70 °C, 50 / 60 Hz 19 kvar(400 / 415 V) 55 °C, 50 / 60 Hz 27.5 kvar(440 V) 40 °C, 50 / 60 Hz 30 kvar(440 V) 55 °C, 50 / 60 Hz 30 kvar(440 V) 70 °C, 50 / 60 Hz 20 kvar(500 / 550 V), 40 °C, 50 / 60 Hz 34 kvar(500 / 550 V) 55 °C, 50 / 60 Hz 34 kvar(500 / 550 V) 70 °C, 50 / 60 Hz 23.5 kvar(690 V) 40 °C, 50 / 60 Hz 45 kvar(690 V) 55 °C, 50 / 60 Hz 45 kvar(690 V) 70 °C, 50 / 60 Hz 32 kvar
rated operational current ac-15 (ie) (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A
rated operational current dc-13 (ie) (24 V) 6 / 144 A(48 V) 2.8 / 134 A(72 V) 2 / 144 A(125 V) 1.1 / 138 A(250 V) 0.55 / 138 A
connecting capacity auxiliary circuit Flexible with Cable End 0.75 ... 2.5 mm2Rigid Cable 1 ... 4 mm2
maximum mechanical switching frequency 3600 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) 8 kV
conventional free-air thermal current (ith) acc. to IEC 60947-5-1, q = 40 °C 16 A
connecting terminals (delivered in open position) main poles M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector