ABB

1SBL337201R7000

Product type: AF45-40-00-70

AF45-40-00 100-250V 50Hz / 100-250V 60Hz / 100-250V DC Contactor

Description

AF45 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. The contactors can also be used for many other applications such lighting... The AF... contactors are fitted with an electronic coil interface which accepts a wide control voltage range, on AC 50/60 Hz or DC supplies. The same contactor can accept various supply voltages according to the different countries where the electrical equipment will be installed, or some fluctuation in the control voltage due to the local supply or network. The AF... contactors are also fully suitable for operation in AC or DC control circuit liable to voltage interruptions or voltage dip risks. Advantages: - Wide voltage range, e.g. 100 ... 250 V AC and DC - Can manage large voltage variations - Reduced power consumption - Very distinct closing and opening - Noise free - Can withstand voltage interruptions or voltage dips in the control supply (≤ 20 ms). The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 4-5 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight1.42 KG / psc.
Commodity number85364900
Country of originFR
Dimensions (WxHxD)92x110x119.5 mm
EAN code3471522114402
Product groupSB
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
standards IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22-2 N°14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
rohs status Following EU Directive 2011/65/EU
operate time Between Coil De-energization and NC Contact Closing 35 ... 115 msBetween Coil De-energization and NO Contact Opening 30 ... 110 msBetween Coil Energization and NO Contact Closing 30 ... 100 ms
terminal type Screw Terminals
cb certificate https://library.abb.com/d/CB_CN45489
ul certificate https://library.abb.com/d/UL_20120830-E312527-10-1
ccc certificate https://library.abb.com/d/CCC_2018010304134049
cqc certificate https://library.abb.com/d/CQC2018010304134049
csa certificate https://library.abb.com/d/CSA_1033838_LR056745
eac certificate https://library.abb.com/d/EAC_RU C-FR ME77 B01010
ul listing card https://library.abb.com/d/UL_E312527
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 2.8 WHolding at Max. Rated Control Circuit Voltage 60 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 2.8 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 210 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
gost certificate https://library.abb.com/d/GOST_POCCFRME77B07175
rohs information https://library.abb.com/d/1SBD250803U1000
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
ambient air temperature Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
environmental information https://library.abb.com/d/1SBD250057E1001
general use rating ul/csa (600 V AC) 80 A
maximum breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 900 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 490 A
rated operational voltage Main Circuit 690 V
number of main contacts nc 0
number of main contacts no 4
object classification code Q
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SBD250803U1000
declaration of conformity - ccc https://library.abb.com/d/2020980304001624
number of auxiliary contacts nc 0
number of auxiliary contacts no 0
connecting capacity main circuit Flexible with Cable End 6 ... 16 mm2Rigid Cable 6 ... 25 mm2
declaration of conformity - ukca https://library.abb.com/d/1SBD250820U1000
short-circuit protective devices gG Type Fuses 80 A
data sheet, technical information https://library.abb.com/d/1SNC001003C0202
mounting by screws (not supplied) 2 x M6 screws placed diagonally
rated operational power ac-3 (pe) (415 V) 25 kW(440 V) 25 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kW
rated control circuit voltage (uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
rated operational current ac-1 (ie) (690 V) 40 °C 70 A(690 V) 55 °C 60 A(690 V) 70 °C 50 A
rated operational current ac-3 (ie) (415 V) 55 °C 37 A(440 V) 55 °C 37 A(500 V) 55 °C 33 A(690 V) 55 °C 25 A(380 / 400 V) 55 °C 37 A(220 / 230 / 240 V) 55 °C 40
connecting capacity auxiliary circuit Flexible with Cable End 0.75 ... 2.5 mm2Rigid Cable 1 ... 4 mm2
maximum electrical switching frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
maximum mechanical switching frequency 300 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) 8 kV
resistance to shock acc. to iec 60068-2-27 Closed, Shock Direction: B1 10 gOpen, Shock Direction: B1 5 gShock Direction: A 20 gShock Direction: B2 15 gShock Direction: C1 20 gShock Direction: C2 20 g
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: