ABB

1SCA162001R1001

Product type: OTDC250UGV22

OTDC250UGV22 PV Disconnect Switch

RoHS Compliant

Description

A fully optimized four-pole DC switch-disconnector to operate 2 circuits with single switch. The new design offers both a size reduction and an increase in efficiency and performance to help manufacturers adapt to the industry’s rapid adoption of 1500V DC solutions. OTDC250UGV22
  • Low Voltage Products and Systems
  • Switches
  • DC Switch-Disconnectors
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight3 KG / psc.
Commodity number85353010
Country of originFI
Dimensions (WxHxD)220x155x260 mm
EAN code6417019920887
Product groupFA
eclass V11.1 : 27371403
etim 5 EC000216 - Switch disconnector
etim 6 EC000216 - Switch disconnector
etim 7 EC000216 - Switch disconnector
etim 8 EC000216 - Switch disconnector
unspsc 39122233
standards UL98B and IEC 60947-1, -3
power loss at Rated Operating Conditions per Pole 7.7 ... 8.4 W
handle type Handle and shaft not included
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
utilization Photovoltaic
ampere rating 250A,1500Vdc,UL98B
mounting type Base mounting
terminal type Lug terminals
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
operating mode Front Operated
shaft diameter 6 mm0.24 in
terminal width 19.5 mm0.77 in
ul certificate https://library.abb.com/d/UL certificate OTDC100-250UG
number of poles 4
protection type Circuit breaker
abb ecosolutions Yes
pollution degree 2
rohs information https://library.abb.com/d/1SCC301239D0201
reach declaration https://library.abb.com/d/1SCC301240D0201
special functions No
tightening torque Cable Lug 15 ... 22 N·mCable Lug 133 ... 195 lbf·in
number of circuits 2
product frame size S2.0
mechanical drawings https://library.abb.com/d/OTDC100-250_G_22_STP, https://library.abb.com/d/1SCC307815F0201
degree of protection Front IP20
utilization category Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B)Switching of single PV string(s) without reverse and overcurrents (DC-PV1)Switching of several PV string(s) with reverse and overcurrents (DC-PV2)
mechanical durability 10000 cycle
connection configuration Double circuit 4a, 4c
end of life instructions https://library.abb.com/d/1SCC301113M0201
maximum operating voltage 1500Vdc, UL 98B
rated operational voltage 1500 V
object classification code Q
position of line terminals Top In - Bottom OutBottom In - Top Out
switches operating mechanism Mechanism Between the Poles22 (Between the Poles)
rated insulation voltage (ui) 1500 V
declaration of conformity - ce https://library.abb.com/d/1SCC301242D2701
group waste to landfill target Non-hazardous waste sent to landfill, where alternative disposal method exists Achieved
declaration of conformity - ukca https://library.abb.com/d/1SCC301313D0201
rated operational current dc-pv1 (1500 V) 200 A
rated operational current dc-pv2 (1500 V) 100 A
data sheet, technical information https://library.abb.com/d/1SCC301022C0201
conventional thermal current (ithe) Fully Enclosed 250 A
short-circuit current rating (sccr) Any UL Listed Fuses or Circuit-Breakers 10 kA1500 V DC
rated operational current dc-21b (ie) (1500 V) 250 A
rated impulse withstand voltage (uimp) 12 kV
environmental product declaration - epd https://library.abb.com/d/1SCC301249D0201
rated short-circuit making capacity (icm) (1500 V DC) 10 kA
improved resource efficiency for customers Product Efficiency - Product considered more energy-efficient compared to similar product on market Achieved
conventional free-air thermal current (ith) q = 40 °C 315 A
circular design principles recyclability rate Design for Closing Resource Loops - Standard EN45555 50,7 %
rated short-time withstand current low voltage (icw) (1500 V DC) 10 kAfor 1 s 10 kA
positive opening operation torque (direct opening action) 6 ... 9 N·m
We’re sorry, our website no longer supports