ABB

1SDA068063R1

Product type: XT3N 250 TMD 125-1250 4p F F InN=50%

XT3N 250 TMD 125-1250 4p F F InN=50%

RoHS Compliant

Description

C.BREAKER TMAX XT3N 250 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 125-1250 A NEUTRAL = 50% PHASES XT3N 250 TMD 125-1250 4p F F InN=50%
  • Low Voltage Products and Systems
  • Circuit Breakers
  • Moulded Case Circuit Breakers
  • Tmax XT
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight2.1 KG / psc.
Commodity number85362090
Country of originIT
Dimensions (WxHxD)155x190x155 mm
EAN code8015644019648
Product groupLA
eclass V11.1 : 27370409
etim 4 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 5 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 6 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 7 EC000228 - Power circuit-breaker for trafo/generator/installation protection
etim 8 EC000228 - Power circuit-breaker for trafo/generator/installation protection
unspsc 39120000
release TMD
version F
sub-type XT3
standards IEC
power loss at Rated Operating Conditions per Pole 6.6 W
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
current type AC/DC
opening time CB with SOR 15 msCB with UVR 15 ms
product name Moulded Case Circuit Breaker
release type TM
setting range 87.5...125 A
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
gl certificate https://library.abb.com/d/1SDL000163R0094
lr certificate https://library.abb.com/d/1SDL000163R0100
order multiple 1 piece
wiring diagram https://library.abb.com/d/1SDM000068R0001
number of poles 4
rohs information https://library.abb.com/d/9AKK108466A1424
product main type SACE Tmax XT
reach declaration https://library.abb.com/d/9AKK108466A1425
e-number (finland) 3641008
rated current (in) 125 A
rated voltage (ur) 690 V
mechanical drawings https://library.abb.com/d/1SDH000720R0100
rated frequency (f) 50 / 60 Hz
electrical durability 120 cycles per hour8000 cycle
mechanical durability 240 cycles per hour25000 cycle
order code us and canada XT3NEN125AFF000XXX
terminal connection type Fixed Circuit-Breakers
environmental information https://library.abb.com/d/9AKK107991A8215
rated operational voltage 690 V AC500 V DC
object classification code Q
rated insulation voltage (ui) 800 V
declaration of conformity - ce https://library.abb.com/d/9AKK106713A5530
short-circuit performance level N
rated uninterrupted current (iu) 250 A
data sheet, technical information https://library.abb.com/d/1SDC210100D0206, https://library.abb.com/d/1SDC210099D0206
circuit breaker type to be associated Power Distribution
rated impulse withstand voltage (uimp) 8 kV
rated service short-circuit breaking capacity (ics) (220 V AC) 37.5 kA(230 V AC) 37.5 kA(240 V AC) 37.5 kA(380 V AC) 27 kA(415 V AC) 27 kA(440 V AC) 18.75 kA(500 V AC) 15 kA(525 V AC) 9.75 kA(690 V AC) 3.75 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 50 kA
rated ultimate short-circuit breaking capacity (icu) (220 V AC) 50 kA(230 V AC) 50 kA(240 V AC) 50 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 25 kA(500 V AC) 20 kA(525 V AC) 13 kA(690 V AC) 5 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 50 kA
rated instantaneous short-circuit current setting (ii) 1250 A