ABB

1SDA070767R1

Product type: E1.2N 800 Ekip G Touch LSIG 3p F F

E1.2N 800 Ekip G Touch LSIG 3p F F

RoHS Compliant

Description

C.BREAKER SACE EMAX2 E1.2N 800 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP/G/TOUCH-LSIG R 800 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED E1.2N 800 Ekip G Touch LSIG 3p F F
  • Low Voltage Products and Systems
  • Circuit Breakers
  • Air Circuit Breakers
  • Emax 2
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight14 KG / psc.
Commodity number85362090
Country of originIT
Dimensions (WxHxD)270x350x330 mm
EAN code8015644746179
Product groupLA
eclass V11.1 : 27370409
etim 4 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 5 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 6 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
etim 7 EC000228 - Power circuit-breaker for trafo/generator/installation protection
etim 8 EC000228 - Power circuit-breaker for trafo/generator/installation protection
release Ekip G Touch LSIG
version F
sub-type E1.2
standards IEC
power loss 50 W
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
current type AC
product name Air Circuit Breaker
release type EL
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
number of poles 3
rohs information https://library.abb.com/d/9AKK108466A1424
product main type SACE Emax 2
reach declaration https://library.abb.com/d/9AKK108466A1425
rated current (in) 800 A
rated voltage (ur) 690 V
electrical durability Ue =< 440 V 8000 cycleUe = 500 ... 690 V 8000 cycle30 cycles per hour
mechanical durability 20000 cycle60 cycles per hour
order code us and canada Z1NPEFBN200A000000XX
terminal connection type Front
environmental information https://library.abb.com/d/9AKK10103A1038
rated operational voltage 690 V AC
object classification code Q
rated insulation voltage (ui) AC 1000 V
declaration of conformity - ce https://library.abb.com/d/9AKK106713A5546
short-circuit performance level N
rated uninterrupted current (iu) 800 A
data sheet, technical information https://library.abb.com/d/1SDC200023D0209
rated impulse withstand voltage (uimp) acc. to IEC 60947-2 12 kV
rated service short-circuit breaking capacity (ics) (220 V AC) 66 kA(230 V AC) 66 kA(380 V AC) 66 kA(400 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 50 kA(660 V AC) 50 kA(690 V AC) 50 kA
rated short-time withstand current low voltage (icw) for 1 s 50 kAfor 3 s 30 kA
rated ultimate short-circuit breaking capacity (icu) (400 V AC) 66 kA(415 V AC) 66 kA(440 V AC) 66 kA(500 V AC) 50 kA(525 V AC) 50 kA(690 V AC) 50 kA
rated service short-circuit breaking capacity, in % of icu (ics) 100 %