| Weight | 5.6 KG / psc. |
| Commodity number | 85362090 |
| Country of origin | |
| Dimensions (WxHxD) | 250x245x285 mm |
| EAN code | 8056221005401 |
| Product group | LA |
| eclass | V11.1 : 27370409 |
| etim 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| etim 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| release | TMA |
| version | F |
| sub-type | XT5 |
| standards | IEC 60947 |
| power loss | 47.8 W |
| rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| current type | AC/DC |
| product name | Moulded Case Circuit Breaker |
| release type | TM |
| setting range | 441...630 A |
| weee category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| order multiple | 1 piece |
| wiring diagram | https://library.abb.com/d/1SDM000005A1001 |
| number of poles | 4 |
| rohs information | https://library.abb.com/d/9AKK108466A1424 |
| product main type | SACE Tmax XT |
| reach declaration | https://library.abb.com/d/9AKK108466A1425 |
| rated current (in) | 630 A |
| mechanical drawings | https://library.abb.com/d/1SDH002011A1101 |
| electrical durability | 120 cycles per hour5000 cycle |
| mechanical durability | 240 cycles per hour20000 cycle |
| order code us and canada | XT5S5463BBFF000XXX |
| terminal connection type | Fixed Circuit-Breakers |
| environmental information | https://library.abb.com/d/9AKK107991A8215 |
| rated operational voltage | 690 V AC750 V DC |
| object classification code | Q |
| rated insulation voltage (ui) | 1000 V |
| declaration of conformity - ce | https://library.abb.com/d/9AKK107680A2824 |
| short-circuit performance level | S |
| rated uninterrupted current (iu) | 630 A |
| data sheet, technical information | https://library.abb.com/d/1SDC210100D0206, https://library.abb.com/d/1SDC210099D0206 |
| circuit breaker type to be associated | Power Distribution |
| rated impulse withstand voltage (uimp) | 8 kV |
| rated service short-circuit breaking capacity (ics) | (220 V AC) 85 kA(230 V AC) 85 kA(240 V AC) 85 kA(380 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(525 V AC) 30 kA(690 V AC) 25 kA(250 V DC) 2 Poles in Series 7.5 kA(500 V DC) 2 Poles in Series 7.5 kA |
| rated short-time withstand current low voltage (icw) | 6 kA |
| rated ultimate short-circuit breaking capacity (icu) | (220 V AC) 85 kA(230 V AC) 85 kA(240 V AC) 85 kA(380 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(525 V AC) 30 kA(690 V AC) 25 kA(250 V DC) 2 Poles in Series 30 kA(500 V DC) 2 Poles in Series 30 kA |
| rated instantaneous short-circuit current setting (ii) | 3150...6300 A |