ABB

1SFA896209R7000

Product type: PSRC30-600-70

PSRC30-600-70 Softstarter - 30 A - 208 ... 600 V AC

RoHS Compliant

Description

The softstarter PSRC30-600-70 has a rated maximum operational current of 30 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSRC features a two-phase control soft start through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The PSRC softstarter range is a true plug-and-play with a fixed setting optimized for scroll compressors. PSRC is often combined with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSRC is fast and easy to install with fixed settings. Designed for scroll compressors results in less stress on the compressor reducing the maintenance cost to a minimum. The PSRC range are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are compressors. PSRC30-600-70
  • Drives
  • Softstarters
  • Softstarters
  • PSR Softstarters
  • PSRC30
  • Low Voltage Products and Systems
  • Control Products
  • Softstarters
  • Softstarters
  • PSR Softstarters
  • PSRC30
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.6 KG / psc.
Commodity number85371091
Country of originCN
Dimensions (WxHxD)137x176x50 mm
EAN code7320500465530
Product groupSG
eclass V11.0 : 27370907
etim 4 EC002572 - Electronic motor control and protection device
etim 5 EC002572 - Electronic motor control and protection device
etim 6 EC002572 - Motor management device
unspsc 39121521
ramp time Fixed settingFixed setting
rohs status Following EU Directive 2002/95/EC August 18, 2005 and amendment
communication FiledBusPlug(Optional)
terminal type Screw Terminals
cqc certificate https://library.abb.com/d/CQC2006010304208086
rohs information https://library.abb.com/d/1SFC132031D0202
run signal relay Yes
product main type PSRC30
tightening torque Control Circuit 0.6 N·mMain Circuit 2.3 N·mSupply Circuit 0.6 N·m
fault signal relay No
overload protection Recommended MS132 25 ... 32
rated frequency (f) 50/60 HzMain Circuit 50 / 60 Hz
abb type designation PSRC30-600-70
ampere rating ul/csa 28 A
by-pass signal relay Yes
degree of protection IP20
overload signal relay No
current limit function No
ambient air temperature Operation -25 ... +60 °CStorage -40 ... +70 °C
global commercial alias PSRC30-600-70
tightening torque ul/csa Control Circuit 5.3 in·lbMain Circuit 20.4Supply Circuit 5.3 in·lb
environmental information https://library.abb.com/d/1SFC132038D0201
rated operational voltage 208 ... 600 V AC
service factor percentage 100 %
object classification code Q
initial voltage during start Fixed setting
declaration of conformity - ce https://library.abb.com/d/2CMT003878
integrated electronic overload No
step down voltage special ramp Fixed setting
declaration of conformity - ccc https://library.abb.com/d/2020980304001088
connecting capacity main circuit Rigid 2 x 0.75 ... 1.5 mm2
maximum operating voltage ul/csa Main Circuit 600 V
data sheet, technical information https://library.abb.com/d/1SFC132012C0201
rated control supply voltage (us) 100 ... 240 V AC
signal indication running r (led) Green
connecting capacity supply circuit Rigid 2 x 0.75 ... 1.5 mm2
rated control circuit voltage (uc) 50 Hz / 60 Hz 100 ... 240 V ACDC Operation 24 V
switch for inside delta connection No
signal indication ramping up/down (led) Green
signal indication completed start ramp (led) Green
starting capacity at maximum rated current ie 4xIe for 6s
rated operational power - in-line connection (pe) (230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kW
signal indication ready to start/standby on (led) Green
rated operational current - in-line connection (ie) 30 A
number of starts per hour at 3.5*ie for 7 sec. 50% on time 50% off time 10
We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: