Product type: AF95B-30-11 100-250V 50/60Hz / DC

AF95B-30-11 100-250V 50/60Hz / DC Contactor

RoHS Compliant

Description

A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 100-250 V, AC/DC AF95B-30-11 100-250V 50/60Hz / DC
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • AF Contactors
  • AF95
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight2.1 KG / psc.
Commodity number85364900
Country of origin
Dimensions (WxHxD)140x170x140 mm
EAN code7320500356432
Product groupSB
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
standards IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
rohs status Following EU Directive 2002/95/EC August 18, 2005 and amendment
operate time Between Coil De-energization and NC Contact Closing 60 ... 130 msBetween Coil De-energization and NO Contact Opening 55 ... 125 msBetween Coil Energization and NC Contact Opening 27 ... 77 msBetween Coil Energization and NO Contact Closing 30 ... 80 ms
terminal type Cable Clamp
bv certificate https://library.abb.com/d/13409/C0 BV
cb certificate https://library.abb.com/d/SE-73661
gl certificate https://library.abb.com/d/GL_20260-04HH
lr certificate https://library.abb.com/d/LR_04-00015-E1
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage DC 2 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage DC 400 W
rina certificate https://library.abb.com/d/ELE060313XG/002
rmrs certificate https://library.abb.com/d/RMRS_12-03683-315
rohs information https://library.abb.com/d/2CMT2016-005489
dimension diagram https://library.abb.com/d/53540923-1
rated frequency (f) Main Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
mechanical durability 10 million
ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
horsepower rating ul/csa (120 V AC) Single Phase 7-1/2 hp(200 ... 208 V AC) Three Phase 30 hp(200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 30 hp(240 V AC) Single Phase 20 hp(440 ... 480 V AC) Three Phase 60 hp(550 ... 600 V AC) Three Phase 75 hp
environmental information https://library.abb.com/d/1SFC101006D0201
general use rating ul/csa (600 V AC) 125 A
maximum breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
rated operational voltage Main Circuit 1000 V
number of main contacts nc 0
number of main contacts no 3
object classification code Q
rated making capacity ac-3 10 x Ie AC-3
rated breaking capacity ac-3 8 x Ie AC-3
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/1SFA1-66
number of auxiliary contacts nc 1
number of auxiliary contacts no 1
connecting capacity main circuit Bar 30 mm2Flexible with Cable End 2 x 6 ... 35 mm2Rigid 2 x 6 ... 65 mm2
declaration of conformity - ukca https://library.abb.com/d/2CMT2020-006118
maximum operating voltage ul/csa Main Circuit 600 V
short-circuit protective devices gG Type Fuses 160 A
data sheet, technical information https://library.abb.com/d/1SBC100192C0206
rated operational power ac-3 (pe) (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(1000 V) 40 kW(380 / 400 V) 45 kW(220 / 230 / 240 V) 25 kW
rated control circuit voltage (uc) DC Operation 20 ... 60 V
rated operational current ac-1 (ie) (690 V) 40 °C 145 A(690 V) 55 °C 135 A(690 V) 70 °C 115 A
rated operational current ac-3 (ie) (415 V) 55 °C 96 A(440 V) 55 °C 93 A(500 V) 55 °C 80 A(690 V) 55 °C 65 A(1000 V) 55 °C 30 A(380 / 400 V) 55 °C 96 A(220 / 230 / 240 V) 55 °C 96
rated operational current dc-1 (ie) (110 V) 2 Poles in Series, 40 °C 145 A(110 V) 2 Poles in Series, 55 °C 135 A(110 V) 2 Poles in Series, 70 °C 115 A(110 V) 3 Poles in Series, 40 °C 145 A(110 V) 3 Poles in Series, 55 °C 135 A(110 V) 3 Poles in Series, 70 °C 115 A(220 V) 3 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 55 °C 135 A(220 V) 3 Poles in Series, 70 °C 115 A
rated operational current dc-3 (ie) (110 V) 2 Poles in Series, 40 °C 145 A(110 V) 2 Poles in Series, 55 °C 135 A(110 V) 2 Poles in Series, 70 °C 115 A(110 V) 3 Poles in Series, 40 °C 145 A(110 V) 3 Poles in Series, 55 °C 135 A(110 V) 3 Poles in Series, 70 °C 115 A(220 V) 3 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 55 °C 135 A(220 V) 3 Poles in Series, 70 °C 115 A(72 V) 1-Pole, 40 °C 130 A(72 V) 1-Pole, 55 °C 130 A(72 V) 1-Pole, 70 °C 115 A
rated operational current dc-5 (ie) (110 V) 2 Poles in Series, 40 °C 145 A(110 V) 2 Poles in Series, 55 °C 135 A(110 V) 2 Poles in Series, 70 °C 115 A(110 V) 3 Poles in Series, 40 °C 145 A(110 V) 3 Poles in Series, 55 °C 135 A(110 V) 3 Poles in Series, 70 °C 115 A(220 V) 3 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 55 °C 135 A(220 V) 3 Poles in Series, 70 °C 115 A
connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 2x0.75 ... 2.5 mm2Solid 1 x 1 ... 4 mm2Stranded 2 x 1 .... 4 mm2
maximum electrical switching frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
maximum mechanical switching frequency 300 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) Main Circuit 8 kV
resistance to shock acc. to iec 60068-2-27 Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
connecting terminals (delivered in open position) main poles M8 hexagon socket screw with single connector