ABB

1SFL467002R3300

Product type: AF146-30-00B-33

AF146-30-00B-33 Contactor

RoHS Compliant

Description

The AF146-30-00B-33 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. AF146-30-00B-33
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • AF Contactors
  • AF146
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight1.3 KG / psc.
Commodity number85364900
Country of originSE
Dimensions (WxHxD)207x150x216 mm
EAN code7320500481004
Product groupSC
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
operate time Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms
terminal type Main Circuit: Bars
bv certificate https://library.abb.com/d/BV_36353_A0BV
cb certificate https://library.abb.com/d/SEMKO_SE-70479M1
gl certificate https://library.abb.com/d/DNV_E-14043
kc certificate https://library.abb.com/d/9AKK107046A9910
lr certificate https://library.abb.com/d/LR_14_70011(E1)
abs certificate https://library.abb.com/d/14-LD1092198-PDA
ccs certificate https://library.abb.com/d/GB14T00030
cqc certificate https://library.abb.com/d/CQC2013010304604055
cul certificate https://library.abb.com/d/20120925-E36588
dnv certificate https://library.abb.com/d/DNV_E-14043
eac certificate https://library.abb.com/d/9AKK107046A8618
prs certificate https://library.abb.com/d/TE_2092_880423_16
ul listing card https://library.abb.com/d/UL_E36588
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage DC 135 W
rina certificate https://library.abb.com/d/ELE060313XG_002
rmrs certificate https://library.abb.com/d/9AKK107045A6978
rohs information https://library.abb.com/d/2CMT2015-005439
dnv gl certificate https://library.abb.com/d/DNV_E-14043
rated frequency (f) Main Circuit 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
coil operating limits (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
mechanical durability 5 million
ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... +70 °C
environmental information https://library.abb.com/d/2CMT004732, https://library.abb.com/d/1SAC200032H0002
rated operational voltage Main Circuit 1000 V
number of main contacts nc 0
number of main contacts no 3
object classification code Q
rated making capacity ac-3 10 x Ie AC-3
rated making capacity ac-3e 12 x Ie AC-3e
rated breaking capacity ac-3 8 x Ie AC-3
rated breaking capacity ac-3e 8.5 x Ie AC-3e
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/2CMT2015-005439
declaration of conformity - ccc https://library.abb.com/d/2020980304001304
number of auxiliary contacts nc 0
number of auxiliary contacts no 0
declaration of conformity - ukca https://library.abb.com/d/2CMT2020-006118
short-circuit protective devices gG Type Fuses 315 A
data sheet, technical information https://library.abb.com/d/1SBC100192C02
rated operational power ac-3 (pe) (415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
rated operational power ac-3e (pe) (415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW
rated operational current ac-1 (ie) (1000 V) 40 °C 225 A(1000 V) 55 °C 200 A(1000 V) 60 °C 200 A(1000 V) 70 °C 175 A(690 V) 40 °C 225 A(690 V) 55 °C 200 A(690 V) 60 °C 200 A(690 V) 70 °C 175 A
rated operational current ac-3 (ie) (415 V) 55 °C 146 A(440 V) 55 °C 146 A(500 V) 55 °C 130 A(690 V) 55 °C 93 A(1000 V) 55 °C 60 A(380 / 400 V) 55 °C 146 A(220 / 230 / 240 V) 55 °C 146
rated operational current ac-3e (ie) (415 V) 60 °C 146 A(440 V) 60 °C 146 A(500 V) 60 °C 130 A(690 V) 60 °C 93 A(1000 V) 60 °C 60 A(380 / 400 V) 60 °C 146 A(220 / 230 / 240 V) 60 °C 146 A
maximum electrical switching frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
maximum mechanical switching frequency 300 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) 8 kV
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 225 A
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
We’re sorry, our website no longer supports