ABB

1SFL587062R1222

Product type: AF305B-30-22RT-12

AF305B-30-22RT-12 Contactor

Description

The AF305B-30-22RT-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 160 kW / 400 V AC (AC-3) or 250 hp / 480 V UL and switching power circuits up to 500 A (AC-1) or 400 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. Includes Mounting kit, containing all neccessary screws, washers and sockets for connecting the terminals, and screws for mounting the device. AF305B-30-22RT-12
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • AF Contactors
  • AF305
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight3.9 KG / psc.
Commodity number85364900
Country of originSE
Dimensions (WxHxD)263x289x203 mm
EAN code7320500509784
Product groupSS
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
standards IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
rohs status Following EU Directive 2011/65/EU
terminal type Main Circuit: Bars
cb certificate https://library.abb.com/d/SE-89316
cqc certificate https://library.abb.com/d/CQC2014010304676670
eac certificate https://library.abb.com/d/9AKK107046A8618
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 17 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 17 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·APull-in at Max. Rated Control Circuit Voltage DC 360 W
rohs information https://library.abb.com/d/2CMT2015-005440
dimension diagram https://library.abb.com/d/1SFB535001G1060
mechanical durability 5 million
horsepower rating ul/csa (200 ... 208 V AC) Three Phase 100 hp(220 ... 240 V AC) Three Phase 125 hp(440 ... 480 V AC) Three Phase 250 hp(550 ... 600 V AC) Three Phase 300 hp
general use rating ul/csa (600 V AC) 400 A
number of main contacts nc 0
number of main contacts no 3
object classification code Q
declaration of conformity - ce https://library.abb.com/d/2CMT2015-005440
declaration of conformity - ccc https://library.abb.com/d/2020980304001305
number of auxiliary contacts nc 2
number of auxiliary contacts no 2
declaration of conformity - ukca https://library.abb.com/d/2CMT2020-006124
data sheet, technical information https://library.abb.com/d/1SBC100192C0204
rated operational power ac-3 (pe) (415 V) 160 kW(440 V) 160 kW(500 V) 200 kW(690 V) 250 kW(1000 V) 132 kW(380 / 400 V) 160 kW(220 / 230 / 240 V) 90 kW
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) 50 Hz / 60 Hz 48 ... 130 VDC Operation 48 ... 130 V
rated operational current ac-1 (ie) (1000 V) 40 °C 375 A(1000 V) 60 °C 325 A(1000 V) 70 °C 260 A(690 V) 40 °C 500 A(690 V) 60 °C 400 A(690 V) 70 °C 325 A
rated operational current ac-3 (ie) (415 V) 55 °C 305 A(440 V) 55 °C 305 A(500 V) 55 °C 290 A(690 V) 55 °C 290 A(1000 V) 55 °C 100 A(380 / 400 V) 55 °C 305 A(220 / 230 / 240 V) 55 °C 305
rated operational current dc-1 (ie) (100 V) 1 Pole, 40 °C 500 A(100 V) 1 Pole, 60 °C 400 A(100 V) 1 Pole, 70 °C 325 A(110 V) 1-Pole, 40 °C 500 A(110 V) 1-Pole, 60 °C 400 A(110 V) 1-Pole, 70 °C 325 A(110 V) 2 Poles in Series, 40 °C 500 A(110 V) 2 Poles in Series, 60 °C 400 A(110 V) 2 Poles in Series, 70 °C 325 A(110 V) 3 Poles in Series, 40 °C 500 A(110 V) 3 Poles in Series, 60 °C 400 A(110 V) 3 Poles in Series, 70 °C 325 A(175 V) 2 Poles in Series, 40 °C 500 A(175 V) 2 Poles in Series, 60 °C 400 A(175 V) 2 Poles in Series, 70 °C 325 A(200 V) 2 Poles in Series, 40 °C 500 A(200 V) 2 Poles in Series, 60 °C 400 A(200 V) 2 Poles in Series, 70 °C 325 A(220 V) 2 Poles in Series, 40 °C 500 A(220 V) 2 Poles in Series, 60 °C 400 A(220 V) 2 Poles in Series, 70 °C 325 A(220 V) 3 Poles in Series, 40 °C 500 A(220 V) 3 Poles in Series, 60 °C 400 A(220 V) 3 Poles in Series, 70 °C 325 A(260 V) 3 Poles in Series, 40 °C 500 A(260 V) 3 Poles in Series, 60 °C 400 A(260 V) 3 Poles in Series, 70 °C 325 A(300 V) 3 Poles in Series, 40 °C 500 A(300 V) 3 Poles in Series, 60 °C 400 A(300 V) 3 Poles in Series, 70 °C 325 A(340 V) 3 Poles in Series, 40 °C 500 A(340 V) 3 Poles in Series, 60 °C 400 A(340 V) 3 Poles in Series, 70 °C 325 A(350 V) 4 Poles in Series, 40 °C 500 A(350 V) 4 Poles in Series, 60 °C 400 A(350 V) 4 Poles in Series, 70 °C 325 A(400 V) 4 Poles in Series, 40 °C 500 A(400 V) 4 Poles in Series, 60 °C 400 A(400 V) 4 Poles in Series, 70 °C 325 A(440 V) 4 Poles in Series, 40 °C 500 A(440 V) 4 Poles in Series, 60 °C 400 A(440 V) 4 Poles in Series, 70 °C 325 A(72 V) 1-Pole, 40 °C 500 A(72 V) 1-Pole, 60 °C 400 A(72 V) 1-Pole, 70 °C 325 A(72 V) 2 Poles in Series, 40 °C 500 A(72 V) 2 Poles in Series, 60 °C 400 A(72 V) 2 Poles in Series, 70 °C 325 A(72 V) 3 Poles in Series, 40 °C 500 A(72 V) 3 Poles in Series, 60 °C 400 A(72 V) 3 Poles in Series, 70 °C 325 A(90 V) 1 Pole, 40 °C 500 A(90 V) 1 Pole, 60 °C 400 A(90 V) 1 Pole, 70 °C 325 A
rated operational current dc-3 (ie) (110 V) 2 Poles in Series, 40 °C 400 A(110 V) 2 Poles in Series, 60 °C 400 A(110 V) 2 Poles in Series, 70 °C 325 A(110 V) 3 Poles in Series, 40 °C 400 A(110 V) 3 Poles in Series, 60 °C 400 A(110 V) 3 Poles in Series, 70 °C 325 A(220 V) 3 Poles in Series, 40 °C 400 A(220 V) 3 Poles in Series, 60 °C 400 A(220 V) 3 Poles in Series, 70 °C 325 A(72 V) 2 Poles in Series, 40 °C 400 A(72 V) 2 Poles in Series, 60 °C 400 A(72 V) 2 Poles in Series, 70 °C 325 A(72 V) 3 Poles in Series, 40 °C 400 A(72 V) 3 Poles in Series, 60 °C 400 A(72 V) 3 Poles in Series, 70 °C 325 A
rated operational current dc-5 (ie) (110 V) 2 Poles in Series, 40 °C 400 A(110 V) 2 Poles in Series, 60 °C 400 A(110 V) 2 Poles in Series, 70 °C 325 A(110 V) 3 Poles in Series, 40 °C 400 A(110 V) 3 Poles in Series, 60 °C 400 A(110 V) 3 Poles in Series, 70 °C 325 A(220 V) 3 Poles in Series, 40 °C 400 A(220 V) 3 Poles in Series, 60 °C 400 A(220 V) 3 Poles in Series, 70 °C 325 A(72 V) 2 Poles in Series, 40 °C 400 A(72 V) 2 Poles in Series, 60 °C 400 A(72 V) 2 Poles in Series, 70 °C 325 A(72 V) 3 Poles in Series, 40 °C 400 A(72 V) 3 Poles in Series, 60 °C 400 A(72 V) 3 Poles in Series, 70 °C 325 A
maximum mechanical switching frequency 300 cycles per hour
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: