ABB

1SFL637001R7022

Product type: AF750-30-22-70

AF750-30-22-70 100-250V 50/60Hz / 100-250V DC Contactor

RoHS Compliant

Description

The AF750-30-22-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. AF750-30-22-70
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
  • AF Contactors
  • AF750
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight13.6 KG / psc.
Commodity number85364900
Country of originSE
Dimensions (WxHxD)280x310x375 mm
EAN code7320500222072
Product groupSC
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
nema size 7
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
operate time Between Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
terminal type Main Circuit: Bars
bv certificate https://library.abb.com/d/BV_13409-C0BV
cb certificate https://library.abb.com/d/SE-82863
gl certificate https://library.abb.com/d/GL_42988-02HH
lr certificate https://library.abb.com/d/16-20064
abs certificate https://library.abb.com/d/15-LD1408622-PDA
ccs certificate https://library.abb.com/d/GB14T00030
cqc certificate https://library.abb.com/d/CQC2007010304256684, https://library.abb.com/d/CQC2012010304540080
csa certificate https://library.abb.com/d/306712-1
cul certificate https://library.abb.com/d/UL_20111101-E36588
dnv certificate https://library.abb.com/d/DNV_E-10966
eac certificate https://library.abb.com/d/9AKK107046A8618
prs certificate https://library.abb.com/d/TE_2092_880423_16
ul listing card https://library.abb.com/d/UL_E36588
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·APull-in at Max. Rated Control Circuit Voltage DC 880 V·A
rina certificate https://library.abb.com/d/ELE060313XG_002
rmrs certificate https://library.abb.com/d/9AKK107045A6978
rohs information https://library.abb.com/d/2CMT2019-005796
dimension diagram https://library.abb.com/d/53540919-60
lovag certificate https://library.abb.com/d/FI105
dnv gl certificate https://library.abb.com/d/TAE00001W1
e-number (finland) 3707173
rated frequency (f) Main Circuit 50 / 60 Hz
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
mechanical durability 3 million
horsepower rating nema (230 V AC) Three Phase 300 Hp(460 V AC) Three Phase 600 Hp(575 V AC) Three Phase 600 Hp
ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... +70 °C
horsepower rating ul/csa (200 V AC) Three Phase 250 hp(208 V AC) Three Phase 250 hp(220 ... 240 V AC) Three Phase 300 hp(440 ... 480 V AC) Three Phase 600 hp(550 ... 600 V AC) Three Phase 700 hp
environmental information https://library.abb.com/d/1SFC101005D0201, https://library.abb.com/d/1SAC200044H0006
general use rating ul/csa (1000 V AC) 900 A(600 V AC) 900 A
maximum breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
rated operational voltage Main Circuit 1000 V
number of main contacts nc 0
number of main contacts no 3
object classification code Q
rated making capacity ac-3 10 x Ie AC-3
rated breaking capacity ac-3 8 x Ie AC-3
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/2CMT2019-005796
declaration of conformity - ccc https://library.abb.com/d/2020980304001301, https://library.abb.com/d/2020980304001045
number of auxiliary contacts nc 2
number of auxiliary contacts no 2
connecting capacity main circuit Bar 52 mm2Rigid Al-Cable 3x185 mm2Rigid Cu-Cable 300 mm2
declaration of conformity - ukca https://library.abb.com/d/2CMT2020-006118
maximum operating voltage ul/csa Main Circuit 1000 V
short-circuit protective devices gG Type Fuses 1000 A
data sheet, technical information https://library.abb.com/d/1SBC100192C0206
rated operational power ac-3 (pe) (415 V) 425 kW(440 V) 450 kW(500 V) 520 kW(690 V) 600 kW(1000 V) 400 kW(380 / 400 V) 400 kW(220 / 230 / 240 V) 220 kW
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
rated operational current ac-1 (ie) (1000 V) 40 °C 1000 A(1000 V) 55 °C 875 A(1000 V) 70 °C 720 A(690 V) 40 °C 1050 A(690 V) 55 °C 875 A(690 V) 70 °C 720 A
rated operational current ac-3 (ie) (415 V) 55 °C 750 A(440 V) 55 °C 750 A(500 V) 55 °C 750 A(690 V) 55 °C 650 A(1000 V) 55 °C 300 A(380 / 400 V) 55 °C 750 A(220 / 230 / 240 V) 55 °C 750
rated operational current dc-1 (ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
rated operational current dc-3 (ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
rated operational current dc-5 (ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 1x0.75 ... 2.5 mm2Solid 1 x 1 ... 4 mm2Stranded 2 x 1 .... 4 mm2
maximum electrical switching frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
maximum mechanical switching frequency 300 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) Main Circuit 8 kV
resistance to shock acc. to iec 60068-2-27 Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A