ABB

1SVR360563R2001

Product type: CP-C.1 24/5.0-C

CP-C.1 24/5.0-C Power supply In:100-240VAC/90-300VDC Out:DC 24V/5A

RoHS Compliant

Description

The CP-C.1 24/5.0-C is a power supply from the CP-C.1 range with coated PCBA. The primary switch mode power supply offers a wide range input of 85-264 V AC and 90-300 V DC, rated input voltage is 110-240 V AC. The rated output power is 120 W, rated output current is 5 A at an output voltage of 24 V DC. The output voltage is adjustable within a range of 22.5 to 28.5 V DC. The power supply provides a U/I output characteristic with a power reserve of up to 50 % and allows parallel operation to increase capacity and to enable redundancy. ATEX and IECEx approvals are available to be used in hazardous area applications. Further features are: power factor correction acc. to EN 61000-3-2. Redundancy unit and buffer modules are available as accessories. CP-C.1 24/5.0-C
  • Low Voltage Products and Systems
  • Control Products
  • Power Supplies
  • CP-C.1
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.75 KG / psc.
Commodity number85044095
Country of originCN
Dimensions (WxHxD)70x160x168 mm
EAN code4013614503849
Product groupEA
eclass V11.0 : 27040701
etim 5 EC002540 - DC-power supply
etim 6 EC002540 - DC-power supply
etim 7 EC002540 - DC-power supply
etim 8 EC002540 - DC-power supply
unspsc 39121004
function Switch mode power supply
standards CAN/CSA C22.2 No.107.1IEC/EN 63000IEC/EN 60079-0IEC/EN 60079-15IEC/EN 60079-7IEC/EN 61000-6-2IEC/EN 61000-6-3IEC/EN 61204UL 508UL 61010-1UL 61010-2-201IEC/EN 61010-1
rohs status Following EU Directive 2011/65/EU
hold-up time (230 V AC) min. 50 ms
output power 120 W
cb certificate https://library.abb.com/d/CB_DK-49193-A2-UL
output current 5 A
abs certificate https://library.abb.com/d/ABS_17-HG1591548-2-PDA
atex certificate https://library.abb.com/d/Type Examination Certificate_DEMKO_16_ATEX_1746X
number of phases 1
pollution degree 2
rohs information https://library.abb.com/d/1SVD982042
culus certificate https://library.abb.com/d/cULus508_20151021-E174460
curus certificate https://library.abb.com/d/cURus60950_E196145-A10-UL, https://library.abb.com/d/cURusANSI-12-12_20160629_E317914
iecex certificate https://library.abb.com/d/IECEx_ULD_170031X
mounting position Position 1; 7
tightening torque Auxiliary Circuit 0.5 N·mInput Circuit 0.5 N·mOutput Circuit 0.5 N·m
dnv gl certificate https://library.abb.com/d/DNV_GL_TAA00000YB_1
e-number (finland) 2712543
rated output power 120 W
input voltage (uin) 85 ... 264 V AC90 ... 300 V DC
rated frequency (f) 50 Hz60 Hz
degree of protection Housing IP20Terminals IP20
mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
rated output current -25 °C ... +60 °C 5 A-40 °C ... +40 °C 7.5 A
rated output voltage 24 V DC
output voltage (uout) 24 V DC
typical input current (115 V AC) 1.1 A(230 V AC) 0.6 A
wire stripping length Auxiliary Circuit 8 mmInput Circuit 8 mmOutput Circuit 8 mm
rated frequency limits 45 ... 65 Hz
ambient air temperature Operation -40 ... +70 °CStorage -40 ... +85 °C
characteristic of output U/I characteristic curve with power reserve
recommended screw driver Input Circuit / Output Circuit PH1Input Circuit / Output Circuit 0.8 x 4
tightening torque ul/csa Input Circuit 4.4 in·lbOutput Circuit 4.4 in·lb
minimum mounting distance Electrical Conductive Board, Horizontal 25 mmElectrical Conductive Board, Vertical 25 mmOther Device Same Type, Horizontal 25 mmOther Device Same Type, Vertical 25 mm
rated input voltage (uin) 100 ... 240 V AC90 ... 300 V DC
object classification code T
output current maximum (iout) 7.5 A
rated insulation voltage (ui) Input Circuit / Output Circuit 300 VInput Circuit / PE 300 VInput Circuit / Relay Contact 300 VOutput Circuit / PE 50 V
declaration of conformity - ce https://library.abb.com/d/1SVD982042-00
declaration of conformity - ukca https://library.abb.com/d/1SVD982042-10
connecting capacity input circuit Flexible with Ferrule 0.5 ... 2.5 mm2Flexible 0.5 ... 2.5 mm2Rigid 0.5 ... 4 mm2
data sheet, technical information https://library.abb.com/d/2CDC114099D0201
connecting capacity output circuit Flexible with Ferrule 0.5 ... 2.5 mm2Flexible 0.5 ... 2.5 mm2Rigid 0.5 ... 4 mm2
electromagnetic compatibility (emc) Immunity - Class BEmission - Class B
surge immunity acc. to iec 61000-4-5 Level 4 Line-to-Ground 4 kVLevel 4 Line-to-Line 2 kV
maximum operating altitude permissible 5000 m
rated impulse withstand voltage (uimp) Input Circuit / Output Circuit 4 kVInput Circuit / PE 4 kVInput Circuit / Relay Contact 4 kVOutput Circuit / PE 0.5 kVOutput Circuit 0.5 kV
connecting capacity input circuit ul/csa Flexible with Ferrule 20-12 AWGFlexible 20-12 AWGRigid 20-10 AWG
connecting capacity output circuit ul/csa Flexible 20-12 AWGRigid 20-10 AWG
resistance to shock acc. to iec 60068-2-27 30g / 3 shocks / 6 ms
resistance to damp heat acc. to iec 60068-2-30 Test Db: 55°C, 2 cycles
resistance to vibrations acc. to iec 60068-2-6 10-58 Hz, ±0.15 mm; 58-150 Hz, 2g, 10 sweep cycles each axis
conducted disturbances immunity acc. to iec 61000-4-6 Level 3 10 V
electrostatic discharge (esd immunity) acc. to iec 61000-4-2 Level 4 Air Discharge 15 kVLevel 4 Contact Discharge 8 kV
radiated electromagnetic field immunity acc. to iec 61000-4-3 Level 3 10 V/m
electrical fast transient (burst immunity) acc. to iec 61000-4-4 Level 4 Power Supply Port Signal 4 kV