ABB

1SVR730850R0300

Product type: CM-ENS.31S

CM-ENS.31S Liquid level monitoring relay 2c/o, sensitivity 0.1-1000kOhm

RoHS Compliant

Description

The CM-ENS.31S belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 24 - 240 V AC/DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. It monitors liquid levels of conductive fluids and protects pumps against dry running or tanks against overflow. The working principle as well as the sensitivity can be selected via front-face potentiometers. Furthermore, an ON-delay or an OFF-delay can be adjusted within a range of 0.1 to 10 s. Several electrodes and a sealable transparent cover for protection against unauthorized changes are available as accessory. The device offers screw connection technology with double-chamber cage connection terminals. CM-ENS.31S
  • Low Voltage Products and Systems
  • Control Products
  • Electronic Relays and Controls
  • Liquid Level Monitors and Controls
  • CM-Enx
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.143 KG / psc.
Commodity number85364900
Country of originDE
Dimensions (WxHxD)97x109x30 mm
EAN code4013614502910
Product groupEA
eclass V11.0 : 27371813
etim 5 EC001447 - (Fill) level monitoring relay
etim 6 EC001447 - (Fill) level monitoring relay
etim 7 EC001447 - (Fill) level monitoring relay
etim 8 EC001447 - (Fill) level monitoring relay
output 2 c/o (SPDT) contacts
function Filling or draining monitoring
standards CAN/CSA C22.2 No.14IEC/EN 63000IEC/EN 60255-27IEC/EN 61000-6-2IEC/EN 61000-6-3UL 508
time range 0 s or 0.1 ... 30 s tripping delay (ON or OFF)
rohs status Following EU Directive 2011/65/EU
terminal type Screw Terminals
cqc certificate https://library.abb.com/d/CQC2015010303819793
eac certificate https://library.abb.com/d/EAC_RU_C-DE.ME77.B.02330
measuring range 01 ... 1000 kΩ
pollution degree 3
rohs information https://library.abb.com/d/1SVD981005-00
culus certificate https://library.abb.com/d/cULus508_20150627-E140448
mounting position 1 ... 5; 1 ... 6
pilot duty ul/csa B300
tightening torque 0.6 ... 0.8 N·mControl Circuit 0.9 N·mMain Circuit 1 N·m
dnv gl certificate https://library.abb.com/d/DNV_GL_TAA00000RW
e-number (finland) 2712568
connecting capacity Flexible with Ferrule 1x 0.5 ... 2.5 mm2Flexible with Ferrule 2x 0.5 ... 1.5 mm2Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm2Flexible 1x 0.5 ... 2.5 mm2Flexible 2x 0.5 ... 1.5 mm2Rigid 1x 0.5 ... 4 mm2Rigid 2x 0.5 ... 2.5 mm2
rated frequency (f) Supply Circuit 50/60 Hz
degree of protection Housing IP50Terminals IP20
mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
number of electrodes 3
overvoltage category III
contact rating ul/csa B300
electrical durability AC-12 100000 cycle
mechanical durability 1000000 cycle
wire stripping length 8 mmMain Circuit 10 mm
ambient air temperature Operation -25 ... +60 °CStorage -40 ... +85 °C
recommended screw driver Pozidriv 14.50.8 x 4
tightening torque ul/csa 7.08 in·lb
connecting capacity ul/csa Flexible 1x 18-14 AWGFlexible 2x 18-16 AWGRigid 1x 20-12 AWGRigid 2x 20-14 AWG
minimum switching capacity 12 V10 mA
object classification code B
rated insulation voltage (ui) Measuring Circuit / Output Circuit 300 VOutput Circuit 1 / Output Circuit 2 300 VSupply Circuit / Measuring Circuit 300 VSupply Circuit / Output Circuit 300 V
declaration of conformity - ce https://library.abb.com/d/1SVD981005-00
declaration of conformity - ccc https://library.abb.com/d/2020980303000198
declaration of conformity - ukca https://library.abb.com/d/1SVD981005-10
maximum operating voltage ul/csa Output Circuit 300 V AC
short-circuit protective devices Output Circuit NC - F Type Fuses 6 AOutput Circuit NO - F Type Fuses 10 A
data sheet, technical information https://library.abb.com/d/2CDC112230D0201
rated control supply voltage (us) 24 ... 240 V AC/DC
rated operational current ac-12 (ie) (230 V) 4 A
rated operational current ac-15 (ie) (230 V) 3 A
rated operational current dc-12 (ie) (24 V) 4 A
rated operational current dc-13 (ie) (24 V) 2 A
maximum operating altitude permissible Without Derating 2000 m
rated impulse withstand voltage (uimp) Measuring Circuit / Output Circuit 4 kVOutput Circuit 1 / Output Circuit 2 4 kVSupply Circuit / Measuring Circuit 4 kVSupply Circuit / Output Circuit 4 kV