| Weight | 0.117 KG / psc. |
| Commodity number | 85364900 |
| Country of origin | DE |
| Dimensions (WxHxD) | 97x109x30 mm |
| EAN code | 4013614502873 |
| Product group | EA |
| eclass | V11.0 : 27371813 |
| etim 5 | EC001447 - (Fill) level monitoring relay |
| etim 6 | EC001447 - (Fill) level monitoring relay |
| etim 7 | EC001447 - (Fill) level monitoring relay |
| etim 8 | EC001447 - (Fill) level monitoring relay |
| output | 1 c/o (SPDT) contact |
| function | Filling or draining monitoring |
| standards | CAN/CSA C22.2 No.14IEC/EN 63000IEC/EN 60255-27IEC/EN 61000-6-2IEC/EN 61000-6-3UL 508 |
| rohs status | Following EU Directive 2011/65/EU |
| terminal type | Screwless Terminals |
| cqc certificate | https://library.abb.com/d/CQC2015010303819793 |
| eac certificate | https://library.abb.com/d/EAC_RU_C-DE.ME77.B.02330 |
| measuring range | 5 ... 100 kΩ |
| pollution degree | 3 |
| rohs information | https://library.abb.com/d/1SVD981005-00 |
| culus certificate | https://library.abb.com/d/cULus508_20150627-E140448 |
| mounting position | 1 ... 5; 1 ... 6 |
| pilot duty ul/csa | B300 |
| tightening torque | Control Circuit 0.9 N·mMain Circuit 1 N·m |
| dnv gl certificate | https://library.abb.com/d/DNV_GL_TAA00000RW |
| e-number (finland) | 2712571 |
| connecting capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm2Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm2Flexible 2x 0.5 ... 1.5 mm2Rigid 2x 0.5 ... 1.5 mm2 |
| rated frequency (f) | Supply Circuit 50/60 Hz |
| degree of protection | Housing IP50Terminals IP20 |
| mounting on din rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| number of electrodes | 3 |
| overvoltage category | III |
| contact rating ul/csa | B300 |
| electrical durability | AC-12 100000 cycle |
| mechanical durability | 1000000 cycle |
| wire stripping length | 8 mmMain Circuit 10 mm |
| ambient air temperature | Operation -25 ... +60 °CStorage -40 ... +85 °C |
| connecting capacity ul/csa | Flexible 2x 18-16 AWGRigid 2x 20-16 AWG |
| minimum switching capacity | 12 V10 mA |
| object classification code | B |
| rated insulation voltage (ui) | Measuring Circuit / Output Circuit 300 VOutput Circuit 1 / Output Circuit 2 300 VSupply Circuit / Measuring Circuit 300 VSupply Circuit / Output Circuit 300 V |
| declaration of conformity - ce | https://library.abb.com/d/1SVD981005-00 |
| declaration of conformity - ccc | https://library.abb.com/d/2020980303000198 |
| declaration of conformity - ukca | https://library.abb.com/d/1SVD981005-10 |
| maximum operating voltage ul/csa | Output Circuit 300 V AC |
| short-circuit protective devices | Output Circuit NC - F Type Fuses 6 AOutput Circuit NO - F Type Fuses 10 A |
| data sheet, technical information | https://library.abb.com/d/2CDC112228D0201 |
| rated control supply voltage (us) | 24 ... 240 V AC/DC |
| rated operational current ac-12 (ie) | (230 V) 4 A |
| rated operational current ac-15 (ie) | (230 V) 3 A |
| rated operational current dc-12 (ie) | (24 V) 4 A |
| rated operational current dc-13 (ie) | (24 V) 2 A |
| maximum operating altitude permissible | Without Derating 2000 m |
| rated impulse withstand voltage (uimp) | Measuring Circuit / Output Circuit 4 kVOutput Circuit 1 / Output Circuit 2 4 kVSupply Circuit / Measuring Circuit 4 kVSupply Circuit / Output Circuit 4 kV |