ABB

2CCL562111E0255

Product type: FS 401E-B25/0.03

FS401 E-B25/0.03 ABB RCBO SMISSLINE TP 1LN ,B, 25A, 30mA, 6kA

RoHS Compliant

Description

Pluggable Residual Current Circuit Breaker with overcurrent Protection for the SMISSLINE TP System acc. IEC/EN/DIN EN 61009-1, EN/DIN EN 61009-2-1 Rated breaking capacity Icn 6kA Tripping characteristic B Rated current In 25A Rated sensitivity I Δn 0.03 Rated voltage Ue 240VAC FS 401E-B25/0.03
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • Plug-in Distribution Systems
  • Plug-in Distribution Systems
  • Residual Current Circuit Breakers with Overcurrent Protection RCBO
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.2 KG / psc.
Commodity number85362020
Country of originCH
Dimensions (WxHxD)36x91x91 mm
EAN code7612270109708
Product groupAF
cn8 85362020
eclass V11.0 : 27142207
etim 7 EC000905 - Earth leakage circuit breaker
etim 8 EC000905 - Earth leakage circuit breaker
standards IEC 61009-1EN 61009-1DIN EN 61009-1EN 61009-2-1DIN EN 61009-2-1
power loss 4.4 W
rohs status Following EU Directive 2002/95/EC August 18, 2005 and amendment
actuator type Toggle
frequency (f) 50/60 Hz
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
weee b2c / b2b Business To Business
number of poles 2
housing material Insulation Group I, RAL 7035
pollution degree 2
rohs information https://library.abb.com/d/2CCC413008D0206_RoHS
actuator material Insulation Group II, Black, Sealable
dimension diagram https://library.abb.com/d/9AKK107492A6192
mounting position Any
tightening torque 2.8 N·m
eplan catalog tree Electrical engineering / Protection devices / General
input voltage type AC
product net length 91 mm
rated current (in) 25 A
rated voltage (ur) 240 V
ambient temperature -25 ... 60 °C
built-in depth (t2) 91 mm
connecting capacity Stranded 0.75 ... 35 mm2Flexible 0.75 ... 25 mm2
rated cross-section 1 - Solid-Core 35 mm24 - Multi-Wired 10 mm2
rated frequency (f) 50 ... 60 Hz
screw terminal type Failsafe Bi-directional Cylinder-lift Terminal
degree of protection IP20
earthing switch type Undelayed
electrical endurance 10000 cycle
leakage current type A
overvoltage category III
energy limiting class 3
maximum surge current 0.25 kA
e-number (switzerland) 809051007
rated residual current 30 mA
dielectric test voltage 2500 V
tripping characteristic B
operating characteristic Instantaneous
type of residual current A type
environmental information https://library.abb.com/d/2CCY451206D0201
number of protected poles 1
rated operational voltage 240 V AC
object classification code FB
contact position indication Red ON / Green OFF
mechanical endurance (nendu) 10000 cycle
position of neutral terminals Right
rated insulation voltage (ui) acc. to IEC/EN 60664-1 500 V
declaration of conformity - ce https://library.abb.com/d/2CCC451036D0201
data sheet, technical information https://library.abb.com/d/9AKK107492A6192
reference ambient air temperature 30 °C
rated short-circuit capacity (icn) (220 V DC) 6 kA
width in number of modular spacings 1
rated impulse withstand voltage (uimp) 4 kV
rated residual breaking capacity (iδm) 6000 A
resistance to vibrations acc. to iec 60068-2-6 2...13.2 Hz/1 mm13.2...100Hz/0.7 g, 5 cycles5...150 ... 5 Hz/1 g, 4 waves