ABB

2CDS272517R0278

Product type: S202UDC-Z2

S202UDC-Z2 Miniature Circuit Breaker - 2P - Z - 2 A

Description

System pro M compact S200UDC current limiting miniature circuit breakers are specially designed for DC applications in the scope of UL489.They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (K,Z), configurations (1P,2P) and rated currents (up to 63A).The Short-circuit current rating SCCR acc. UL489 is 14 kA. The S200UDC is suitable for DC voltages up to 125 VDC (2 pole). All MCBs of the product range S200UDC comply with UL489, allowing the use for commercial and industrial applications..
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • Miniature Circuit Breakers MCBs
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.3 KG / psc.
Commodity number85362010
Country of originDE
Dimensions (WxHxD)35x85x69 mm
EAN code4016779825375
Product groupAB
cn8 8536 20 10
eclass V11.0 : 27141901
etim 7 EC000042 - Miniature circuit breaker (MCB)
etim 8 EC000042 - Miniature circuit breaker (MCB)
unspsc 39121614
remarks Please note polarity of device
standards UL 489
power loss 5 Wat Rated Operating Conditions per Pole 2.5 W
rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
terminal type Double Clamp
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
weee b2c / b2b Business To Business
number of poles 2
pole net weight 0.14 kg
actuator marking I / O
housing material Insulation Group I, RAL 7035
pollution degree 3
rohs information https://library.abb.com/d/2CDK400630D2702
actuator material Insulation Group II, Black, Sealable
installation size acc. to DIN 43880 2
mounting position Any
tightening torque 2.8 N·m
eplan catalog tree Electrical engineering / Protection devices / General
input voltage type DC
rated current (in) 2 A
built-in depth (t2) 69 mm
connecting capacity Busbar 10 / 10 mm2Flexible with Ferrule 0.75 ... 16 mm2Flexible 0.75 ... 16 mm2Rigid 0.75 ... 25 mm2Stranded 0.75 ... 25 mm2
rated frequency (f) DC
screw terminal type Failsafe Bi-directional Cylinder-lift Terminal
certification agency UL
degree of protection IP20Enclosure with Cover IP40
mechanical endurance 20000 cycle
mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
overvoltage category III
accessories available Yes
energy limiting class 3
ambient air temperature Operation -25 ... +55 °CStorage -40 ... +70 °C
power supply connection Please Note Polarity of Device
tripping characteristic Z
environmental conditions 28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 %
recommended screw driver Pozidriv 2
tightening torque ul/csa 25 in·lb
environmental information https://library.abb.com/d/9AKK107680A6947
eplan function definition Circuit breaker / Double circuit-breaker / Double circuit breaker 1_2_3_4
number of protected poles 2
rated operational voltage 125 V DCacc. to IEC 60947-2 125 V
connecting capacity ul/csa Busbar 18-8 AWGConductor 18-4 AWG
object classification code F
contact position indication Red ON / Green OFF
rated short-circuit capacity (230 V AC) 14 kA
rated insulation voltage (ui) 440 V
declaration of conformity - ce https://library.abb.com/d/2CDK400630D2702
maximum operating voltage ul/csa 250 V DC
data sheet, technical information https://library.abb.com/d/No document needed
interrupting rating acc. to ul489 (125 V DC) 14 kA(250 V DC) 14 kA
interrupting rating acc. to ul1077 (125 V DC) 14 kA
width in number of modular spacings 2
rated impulse withstand voltage (uimp) 4 kVat 2000 m 5 kVat Sea Level 6.2 kV
resistance to shock acc. to iec 60068-2-27 30g / 3 shocks / 11 ms
rated conditional short-circuit current (inc) (230 V) 14 kA
resistance to vibrations acc. to iec 60068-2-6 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
rated service short-circuit breaking capacity (ics) (230 V AC) 14 kA
rated ultimate short-circuit breaking capacity (icu) (230 V AC) 14 kA