Product type: DS201 C20 A30

Residual Current Circuit Breaker with Overcurrent Protection DS201 - 1P+N - 30 mA - 20 A - C - Type A

RoHS Compliant

Description

The DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts. DS201 C20 A30
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • Residual Current Devices RCDs
  • Residual Current Circuit Breakers with Overcurrent Protection RCBO
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.2 KG / psc.
Commodity number85363030
Country of originIT
Dimensions (WxHxD)0.035x0.085x0.069 m
EAN code8012542738510
Product groupAM
cn8 85363030
eclass V11.0 : 27142207
etim 7 EC000905 - Earth leakage circuit breaker
etim 8 EC000905 - Earth leakage circuit breaker
standards IEC/EN 61009-1, IEC/EN 61009-2-1
cable size 25 mm2
power loss 3.6 W
eplan macro 9AKK107680A0597
housing type Insulation group I - II, RAL 7035
release type C
actuator type Toggle - Insulation group II, Black RAL 9005,sealable in ON-OFF positions
frequency (f) 50/60 Hz
mounting type on DIN rail EN 60715 (35mm) by means of mounting clip
terminal type Screw Terminals
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
accessory type Auxiliary contactSignal contact / auxiliary contactShunt tripAuxiliary contact for bottom fittingUndervoltage releaseOvervoltage releaseMotor operating device
cb certificate https://library.abb.com/d/9AKK107492A6060
weee b2c / b2b Business To Consumer
abs certificate https://library.abb.com/d/9AKK107991A2823
ccc certificate https://library.abb.com/d/9AKK107492A6067
eac certificate https://library.abb.com/d/9AKK107492A6071, https://library.abb.com/d/9AKK107991A7755
number of poles 2
sev certificate https://library.abb.com/d/9AKK107680A1558, https://library.abb.com/d/9AKK107680A1560
vde certificate https://library.abb.com/d/9AKK107492A6092
fault indication Blue flag on toggle
gost certificate https://library.abb.com/d/9AKK107992A1640
kema certificate https://library.abb.com/d/9AKK107492A6076
pollution degree 2
rmrs certificate https://library.abb.com/d/9AKK107680A3454, https://library.abb.com/d/9AKK107680A3455
rohs information https://library.abb.com/d/2CSC422002K2701
e-number (sweden) 2100429
mounting position Any
test voltage (ut) 170 ... 264 V
tightening torque 2.8 N·m
dnv gl certificate https://library.abb.com/d/9AKK107680A3457, https://library.abb.com/d/9AKK107680A3456
e-number (finland) 3211157
eplan catalog tree Electrical engineering / Protection devices / Ground fault current circuit breaker
input voltage type AC
rated current (in) 20 A
rated voltage (ur) 230 V
ambient temperature -25...55 °C
built-in depth (t2) 69 mm
connecting capacity Busbar 10 ... 10 mm2Stranded 0.75 ... 25 mm2Flexible with Ferrule 0.75 ... 16 mm2Flexible 0.75 ... 16 mm2
number of batteries 0
rated frequency (f) 50/60 Hz
screw terminal type Failsafe Bi-directional Cylinder-lift Terminal
degree of protection Terminals IP20Housing IP40
electrical endurance 10000 cycle
leakage current type A
overvoltage category III
accessories available Yes
energy limiting class 3
öve certificate https://library.abb.com/d/9AKK107492A6085
wire stripping length 12 mm
rated residual current 30 mA
ambient air temperature Operation -25...55 °C
dielectric test voltage 2 kV
power supply connection Arbitrary
tripping characteristic C
environmental conditions 28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 %
operating characteristic Instantaneous
type of residual current A type
environmental information https://library.abb.com/d/2CSC422002K2701
number of protected poles 1
rated operational voltage 230 / 240 V AC
object classification code F
contact position indication Red ON / Green OFF
mechanical endurance (nendu) 20000 cycle
position of neutral terminals Right
rated insulation voltage (ui) 500 V
declaration of conformity - ce https://library.abb.com/d/9AKK106713A5588
data sheet, technical information https://library.abb.com/d/9AKK107492A6187
reference ambient air temperature 30 °C
rated short-circuit capacity (icn) 6 kA
short-circuit current rating (sccr) 0.03 A
width in number of modular spacings 2
number of modular spacings per din rail 2
primary rated impulse withstand voltage 4 kV
resistance to shock acc. to iec 60068-2-27 25g / 2 shocks / 13 ms
rated residual breaking capacity (iδm) EN 61009-1 6000 AIEC 61009-1 6000 A
rated conditional short-circuit current (inc) 10 kA
resistance to vibrations acc. to iec 60068-2-6 0.1 mm or 1 g - 20 cycles at 5...150...5 Hz
rated service short-circuit breaking capacity (ics) 7.5 kA
rated ultimate short-circuit breaking capacity (icu) 10 kA