ABB

2CTB803972R1400

Product type: OVR T2 1N 40-440 P TS QS

OVR T2 1N 40-440 P TS QS Surge Protective Device

RoHS Compliant

Description

Type 2 SPD’s are designed to discharge the currents generated by indirect lightning strikes causing induced or conducted overvoltages on the power distribution network. They are characterized by an 8/20μs waveform (Imax). Higher is the Imax, more powerful they are. They are installed in the main distribution switchboard but also in sub-distribution board. They have a low residual voltage Up often compatible with the withstand voltage of the equipment to protect. If this is not the case or the cable length to the equipment is longer than 10m, another level of coordination with OVR T2-T3, OVR T3 will be needed. OVR T2 1N 40-440 P TS QS
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • Surge Protective Devices SPDs
  • Surge Protective Devices SPD Class II
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 6-9 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.24 KG / psc.
Commodity number85369095
Country of originBG
Dimensions (WxHxD)0.036x0.095x0.058 m
EAN code3660308524577
Product groupAK
cn8 85363090
eclass V11.0 : 27130805
etim 7 EC000941 - Surge protection device for power supply systems
etim 8 EC000941 - Surge protection device for power supply systems
version Plug-in
fuse size 2 modular spacing
standards IEC 61643-1 / EN 61643-11
rohs status Following EU Directive 2011/65/EU
frequency (f) 45 ... 65 Hz
mounting type DIN rail (top hat rail) 35 mm
weee category 5. Small Equipment (No External Dimension More Than 50 cm)
arrester class II
ul certificate https://library.abb.com/d/-
weee b2c / b2b Business To Business
cqc certificate https://library.abb.com/d/9AKK107680A1974
impulse current I (imp, 10 / 350 μs) 2 kA
number of poles 2
rohs information https://library.abb.com/d/9AKK108466A4410
discharge current Nominal (8 / 20 μs) 20 kAI (max, 8 / 20 μs) 40 kAI (total, 8 / 20 μs) 80 kA
rated voltage (ur) 230 V AC
degree of protection IP20
number of conductors 2
transmission standard Optic
ambient air temperature Operation -40 ... +80 °CStorage -40 ... +80 °C
number of protected poles 2
rated connecting capacity L/N Terminals with Solid Conductor 2.5 ... 35 mm2L/N Terminals with Stranded Conductor 2.5 ... 25 mm2PE Terminals with Solid Conductor 4 ... 14 mm2PE Terminals with Stranded Conductor 2 ... 14 mm2
object classification code 141DCC
short circuit withstand icc 100 kA
declaration of conformity - ce https://library.abb.com/d/9AKK108466A4410
flammability according to ul94 V-0
preventive maintenance feature No
voltage protection level ( up) 1.5 kV(L-N) 1.25 kV(N-PE) 1.4 kV
number of auxiliary contacts no 1
short-circuit protective devices Curve B Breakers ≤ 125 ACurve C Breakers ≤ 125 AgL Type Fuses ≤ 125 AgG Type Fuses ≤ 125 A
data sheet, technical information https://library.abb.com/d/No document needed
nominal ac voltage of the system (uo) 400 / 690 V
maximum operating altitude permissible Without Derating 5000 m
type of low voltage distribution system TTTN-S
maximum continuous operating voltage (uc) (L-PE) 440 V(L-N) 440 V(N-PE) 440 V
rated service short-circuit breaking capacity (ics) 100 kA