ABB

SK827041-AR

Product type: EK550-40-11 400-415V 50Hz

EK550-40-11-AR Schütz 400-415V 50Hz

Description

Die AC-betätigten 4-poligen EK550-Schütze werden hauptsächlich zum Schalten von Motoren, nicht oder leicht induktiver Leistungskreise bis 1000V AC und 600V DC eingesetzt. Alle nachträglich anbaubare Öffner-Hilfskontakte sind als Mirrorkontakte nach IEC60947-5-1 Anhang L ausgeführt. Weiteres Zubehör wie Verdrahtungshilfen sowie Verriegelungsglieder u.a. ergänzen das Sortiment.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 4-5 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight15.5 KG / psc.
Commodity number85365080
Country of originBG
Dimensions (WxHxD)0.27x0.272x0.226 m
EAN code7320500012062
Product groupSC
eclass V11.0 : 27371003
etim 4 EC000066 - Magnet contactor, AC-switching
etim 5 EC000066 - Magnet contactor, AC-switching
etim 6 EC000066 - Power contactor, AC switching
etim 7 EC000066 - Power contactor, AC switching
etim 8 EC000066 - Power contactor, AC switching
unspsc 39121529
rohs status Following EU Directive 2011/65/EU
operate time Between Coil De-energization and NC Contact Closing 10 ... 20 msBetween Coil De-energization and NO Contact Opening 13 ... 23 msBetween Coil Energization and NC Contact Opening 25 ... 55 msBetween Coil Energization and NO Contact Closing 30 ... 60 ms
terminal type Main Circuit: Bars
cqc certificate https://library.abb.com/d/CQC2003010304094982
coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 140 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
rohs information https://library.abb.com/d/2CMT2016-005940
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
coil operating limits (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
mechanical durability 5 million
ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -50 ... +70 °C
environmental information https://library.abb.com/d/1SFC101013D0201
general use rating ul/csa (600 V AC) 540 A
rated operational voltage Main Circuit 1000 V
number of main contacts nc 0
number of main contacts no 4
object classification code Q
rated making capacity ac-3 10 x Ie AC-3
rated breaking capacity ac-3 8 x Ie AC-3
rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
declaration of conformity - ce https://library.abb.com/d/2CMT2015-005442
declaration of conformity - ccc https://library.abb.com/d/2020980304001264
number of auxiliary contacts nc 1
number of auxiliary contacts no 1
short-circuit protective devices gG Type Fuses 800 A
data sheet, technical information https://library.abb.com/d/1SBC100122C0202
rated operational power ac-3 (pe) (415 V) 315 kW(440 V) 315 kW(500 V) 400 kW(690 V) 500 kW(1000 V) 35 kW(380 / 400 V) 280 kW(220 / 230 / 240 V) 160 kW
idea granular category code (igcc) 4755 >> Contactors
rated control circuit voltage (uc) 50 Hz 400 ... 415 V
rated operational current ac-1 (ie) (1000 V) 40 °C 800 A(1000 V) 60 °C 650 A(1000 V) 70 °C 575 A(690 V) 40 °C 800 A(690 V) 55 °C 650 A(690 V) 60 °C 650 A(690 V) 70 °C 575 A
rated operational current ac-3 (ie) (440 V) 55 °C 550 A(500 V) 55 °C 550 A(690 V) 55 °C 550 A(1000 V) 55 °C 175 A(380 / 400 V) 55 °C 550 A(220 / 230 / 240 V) 55 °C 550
maximum electrical switching frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 120 cycles per hour(AC-3) 300 cycles per hour
maximum mechanical switching frequency 3600 cycles per hour
maximum operating altitude permissible Without Derating 3000 m
rated impulse withstand voltage (uimp) 8 kV
conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 A
rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A
connecting terminals (delivered in open position) main poles Flat type c/w screws and bolts