| Weight | 0.041 KG / psc. |
| Commodity number | 85365019 |
| Country of origin | LK |
| Dimensions (WxHxD) | 180x17x215 mm |
| EAN code | |
| Product group | B |
| Type of switching function | Normally open contact (NO) |
| Type of electrical connection | Cable |
| Type of switching output | PNP |
| Rated switching current | 200mA |
| Relative hysteresis | 10% |
| Correction factor (aluminum) | 0.5 |
| Correction factor (copper) | 0.45 |
| Correction factor (brass) | 0.55 |
| Correction factor (St37) | 1 |
| Correction factor (stainl steel) | 0.8 |
| No-load current | 10mA |
| Relative repeat accuracy | 1.25% |
| Residual ripple | 20% |
| Switching distance | 0.8mm |
| Switching frequency | 5,000Hz |
| Switching behavior of the output | Static |
| Voltage drop | 2V |
| Supported communication interface | IO-Link |
| Display | LED display |
| | Short circuit protection, Reverse polarity protection |
| Line diameter | 2.6mm |
| Conductor cross-section | 0.14mm² |
| Number of cores | 3 |
| Alignment of cable entry | axial |
| Design | Cylinder, screw-thread |
| Thread pitch | 0.5mm |
| Cable length | 2m |
| Cable infeed | axial |
| Length | 25mm |
| Storage temperature | -40 - 80°C |
| Maximum tightening torque | 1.5Nm |
| Mechanical mounting condition for sensor | flush |
| Degree of protection (IP) | IP67 |
| Active area material of sensor | Plastic (PA6.6) |
| Housing material | Stainless steel |
| Material of cable sheath | Silicone |
| Thread dimension | M5 |
| Ambient temperature | -25 - 120°C |
| Reference medium / object | Standard measuring plate FE360 5x5x1mm |
| IO-Link version | V1.0.1 |
| Reach-compliant | Yes |
| UL / CSA approval number | E486083 |
| TSCA-compliant | Yes |
| IPF Product Group | 202 inductive sensors (high temperature) |
| | 0,23kg CO₂e |