| Weight | 0.02 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | AP-N10 |
| Type | Single output type |
| Applicable sensor head | AP-41M, AP-41, AP-43, AP-44, AP-48 |
| Configuration/Display range | -15 to +110 % of F.S. |
| Repeatability | ±0.2 % of F.S. |
| Display resolution | AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa |
| Eco mode | 560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less) |
| Expansion units | Max. 16 units (Dual output type is counted as 2 units.) *1 |
| Control output(s) | 1 *2 |
| Display temperature characteristic | ±1 % of F.S. (When the temperature varies from 25 °C 77 °F ) |
| Response time (Chattering prevention function) | 1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable |
| Relative humidity | 35 to 85 % RH (No condensation) |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions |
| Shock resistance | 500 m/s 2 , 3 times in each of the X, Y, and Z directions |
| Material | Main unit and cover: Polycarbonate |
| Normal | 770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less) |
| Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2 |
| Ambient temperature | 0 to +50 °C 32 to 122 °F (No freezing) *3 |