| Weight | 0.15 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | EV-118M |
| Type | Shielded |
| Shape | M18 |
| Detecting distance | 5 mm 0.20" ±10% |
| Detectable object | Ferrous metals (see Characteristics for nonferrous metals) |
| Standard target (iron, t=1 mm 004" ) | 18 x 18 mm 0.71" x 0.71" |
| Hysteresis | 10% max. of detecting distance |
| Response frequency | 350 Hz |
| Operation mode | N.O. |
| Temperature characteristics | ±10% max. of detecting distance at 23°C 73.4°F , within -25 to +70°C -13 to +158°F |
| Control output (switching capacity) | 5 to 200 mA |
| Protection circuit | Reversed polarity, short-circuit, surge voltage |
| Cable length | 2 m 6.6' |
| Current consumption (leakage current) | Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
| Residual voltage | Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
| Ambient temperature | -25 to +80 °C -13 to 176 °F (No freezing) |
| Relative humidity | 35 to 95 % RH (No condensation) |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions |
| Shock resistance | 1,000 m/s 2 , 3 times in each of the X, Y, and Z directions |
| Case material | Nickel-plated brass |
| Accessories | Nut × 2, toothed washer × 1, instruction manual |
| Power voltage | 12 to 24 VDC, Ripple (P-P) 20 % or less |
| Enclosure rating | IP67 |