Product AttributeAttribute Value
Weight2.2 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)
EAN code
Product group
Model FD-G25L
NPS (Nominal Pipe Size) 3/4", 1"
Outer diameter of pipe ø25 to 29 mm 0.98" to 1.14" , ø32 to 36 mm 1.26" to 1.42"
Pipe thickness 1.5 to 3.0 mm 0.06" to 0.118"
Supported pipe materials Iron, steel, stainless steel
Supported fluids Air, Nitrogen, other gases *1
Fluid temperature 0 to 60ºC 32 to 140 °F
Recommended pressure 0.4 MPa or greater (58 PSI or greater)
Rated velocity of flow range Up to 15 m/s
L/min Pipe size 20 A: 330.0 Pipe size 25 A: 540.0
CFM Pipe size 20 A: 12.00 Pipe size 25 A: 19.00
20°C 68°F 80 psi 055 MPa Pipe size 20 A: 72.06 Pipe size 25 A: 114.10
20°C 68°F 100 psi 069 MPa Pipe size 20 A: 87.28 Pipe size 25 A: 138.20
20°C 68°F 120 psi 083 MPa Pipe size 20 A: 102.50 Pipe size 25 A: 162.30
Display QVGA 2.2" LCD color monitor
Display update cycle Approx. 3 Hz
Consumption/leakage amount 0.001 m 3 , 1 L, 0.1 CF
Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
Between 1 and 10% of FS ±1.0% of F.S. *2 *3 *4 *5
Zero point error ±0.15% of F.S. *2 *6
Static leakage repeatability ±1.0% of RD *4 *7
Hysteresis Variable
Flow units CFM(S), CFM, m 3 /h (N), m 3 /h (S), m 3 /h, L/min (N), L/min (S), L/min
I/O wiring connection port M12 4-pin connector (male)
ch2 Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input *8
Analog output (ch2) 4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less
External input (ch2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more
Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output
Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less
Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)
Transmission rate 100 Mbps
Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable
Connector M12 connector (female, D-code)
Network function Modbus TCP, EtherNet/IP™, IO-Link *9
Events 100
Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), 550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)
Ambient temperature Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)
Relative humidity 5 to 85%RH (no condensation)
Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G 2 /Hz, XYZ axes
Shock resistance 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
Detection head Body: PPS/SUS304, rear surface: rubber
Mounting/damping bracket SUS304
DN (Diameter Nominal) 20 A, 25 A
m 3 /h Pipe size 20 A: 20.00 Pipe size 25 A: 32.00
20°C 68°F 60 psi 041 MPa Pipe size 20 A: 56.84 Pipe size 25 A: 90.00
Instantaneous flow rate 0.01 m 3 /h, 0.1 L/min, 0.001 CFM
Between 10 and 100% of FS ±2.0% of RD *2 *3 *4 *5
ch1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump) *8
Control output (ch1/ch2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less
USB USB 2.0
Standard IEEE 802.3u (100BASE-TX)
Consumption amount/ leakage amount Approx. 5 years
Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2
Enclosure rating IP65/67 (IEC 60529) *10
Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating