| Weight | 0.77 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | FD-H22F |
| Type | Hose model |
| Supported pipe diameter | ø13–22.9 ø0.51"-0.90" |
| Supported pipe materials | Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.) *1 |
| Supported fluids | All fluids (water, oil, chemicals, etc.) *1 |
| Supported fluid temperature | 0–100°C 32–212°F (no freezing on pipe surface) *2 |
| Maximum rated flow | 60 L/min 15.9 gal/min |
| Zero cut flow rate | 0.5 L/min 0.13 gal/min (variable, initial value) |
| Detection principle | Delta TOF |
| Function for automatic correction for speed of sound in liquid | — |
| Display | QVGA 2.0 model: color LCD, status indicator light |
| Display update cycle | Approx. 10 times/second |
| Integrated flow | 0.01/0.1/1 (L) (default value: 0.1; up to 8 digits) |
| Response time | 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
| Measurement accuracy | — |
| Repeatability | 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S. *3 *4 |
| Hysteresis | Variable |
| Flow units | L/min m 3 /h G/min |
| Pulse output increments (L) | 0.02–999.99 |
| Pipe temperature measurement accuracy | — |
| Network support | IO-Link *5 |
| Display resolution | Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1) *6 |
| Pulse output increments (MJ) | 0.02–999.99 *6 |
| Data reading | USB2.0 |
| Power I/O connector | M12 8-pin connector (male) |
| Analog output (Ch1/2) | 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
| External input (Ch2/3) | Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input Short circuit current: 1.5 mA or less; input time: 20 ms or more |
| Current consumption | 240 mA or less (when using flow sensor standalone; with analog output; excluding load current) *7 |
| Protection circuit | Protection against reverse power connection, power supply surges, output short circuits, and output surges |
| Ambient temperature | Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing) *2 |
| Relative humidity | 35–85% RH (no condensation) |
| Vibration resistance | 10–500 Hz; Power spectral density: 0.816 G 2 /Hz; X, Y and Z directions |
| Shock resistance | 100 m/s 2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes |
| Sensor head | Body: PPS/PET/PAR/SUS304; Cable: PVC Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7 |
| Instantaneous flow | 0.01/0.1/1 (L/min) (default value: 0.1) |
| Unit | MJ/h kW kBTU/h *6 |
| Accumulation period | Approx. 1 year |
| Output (Ch1/2/3/4) | Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less |
| Power voltage | 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
| Enclosure rating | IP65/67 (IEC 60529) *8 |
| Display unit | Body: PPS/PET/POM; Display window: PAR |