| Weight | 0.4 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | FD-Q20C |
| Supported pipe diameter | 1/2" (15 A), ø18 to ø23 (mm) 3/4" (20 A), ø23 to ø28 (mm) |
| Supported pipe materials | Metal pipe/Resin pipe *1 |
| Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.] *1 |
| Supported fluid temperature | 0 to 85°C 32 to 185°F (No freezing on the pipe surface) *2 |
| Maximum rated flow | 1/2" (15 A): 60 L/min, 15.9 G/min 3/4" (20 A): 100 L/min, 26.4 G/min |
| Zero cut flow rate | 2.5 L/min (Default) *3 |
| Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
| Display update cycle | Approx. 3 Hz |
| Display resolution | 0.1/ 1 (Default : 0.1) (L/min) |
| Response time | 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
| Protection circuit | Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection |
| Repeatability | 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S. *4 (Specific to selected response time)) |
| Hysteresis | Variable |
| Integrated flow unit display | 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L) |
| Integrated flow data storage cycle | Save to memory every 10 seconds |
| Memory backup | EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
| Power I/O connector | M12 4-pin connector |
| Analog output (ch2) | 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less *5 |
| External input (ch2) | Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more *5 |
| Current consumption | 100 mA or less (Load current excluded) *6 |
| Ambient temperature | -10 to +60 °C 14 to 140 °F (No freezing) |
| Relative humidity | 35 to 85 % RH (No condensation) |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions |
| Shock resistance | 100 m/s 2 , 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
| Sensor surface | Rubber |
| Mounting bracket | SUS304/PA/SUSXM7 |
| Output (ch1/ch2) | Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less *5 |
| Power voltage | 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
| Enclosure rating | IP65/IP67 (IEC60529) |
| Sensor main unit | PPS/PES/PBT/SUS303/SUS304/SUSXM7 |