| Weight | 0.25 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | FD-XS8E |
| Supported pipe materials | Metal pipes, Plastic pipes (soft/hard) *1 |
| Supported fluids | Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1 |
| Supported fluid temperature | 0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature) |
| Metal pipe attachment | FD-XC8M *2 |
| Maximum rated flow rate | Outer diameter of pipe ø 6 0.24 " , 1/4 " (6.35 mm) : 3000 mL/min Outer diameter of pipe ø 8 0.31 " : 8000 mL/min |
| Zero cut flow rate | 50 mL/min *3 (variable, default) |
| Repeatability | Response time 50 ms: ±20 % of RD Response time 500 ms: ±15 % of RD |
| Hysteresis | Variable |
| Display method | Status indicator |
| Ambient temperature | -10 to 60 °C 14 to 140 °F (No freezing) |
| Relative humidity | 35 % to 85 %RH (No condensation) |
| Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm 0.06 " , 2 hours each for X,Y,Z direction |
| Shock resistance | 50 G 11 ms 3 times each for X,Y,Z direction |
| For metal pipe | Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 |
| Plastic pipe/tube attachment | FD-XC8R1, FD-XC8R2, FD-XC8R3 |
| Instantaneous flow rate | 1/10 mL/min (Displayed on controller) |
| Enclosure rating | IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4 |
| Sensor head | Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM |
| For plastic pipe | Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 |