KEYENCE

FL-S001

Product type: FL-S001

Amplifier Unit, Sanitary Specification

  • Process Controls / Process Sensors
  • Level Sensors
  • Sensing Guide Pulse Level Sensor
  • Models
  • Amplifier Unit, Sanitary Specification
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.67 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)
EAN code
Product group
Model FL-S001
Type Sanitary type
Measurement range 200 to 2,000 mm 7.87" to 78.74"
Specific conductive capacity of measurable media 2 or more *1
Resolution 1 mm 0.04" *2
Linearity ±3 mm ±0.12" *2
Temperature characteristics 0.1 mm/°C
Bottom side 65 mm 2.56" max. *3
Judgment output response time 0.4 s minimum
Probe horizontal torque 6 N m
Tank pressure -0.1 to +1 Mpa
Connection port 2S ferrule
Analog output 4 to 20 mA, maximum load resistance: 350 Ω (Response time: 0.1 s after comparator output determined [90 % response]) Ripple when target remains stationary (P-P) 2 % of F.S. max.
Network compatibility IO-Link *4
Zero accuracy ±0.1 mA (Zero point = 4 mA)
Full scale accuracy ±0.2 mA (full scale = 20 mA)
Applicable cable 8-pin M12 connector
Current consumption 300 mA max. (at 10 V)/120 mA max. (at 30 V) (excluding load)
Ambient temperature -20 to +60 °C -4 to +140°F
Relative humidity 35 to 85 % RH (No condensation)
Operating medium temperature -20 to +150 °C -4 to 302 °F
Vibration resistance 10 to 55 Hz, 0.75 mm 0.03" double amplitude in X, Y and Z directions, 2 hours respectively
Shock resistance 300 m/s 2 in 6 directions, 3 times respectively
Case Metal section of the housing: SUS304 Plastic section of the housing: PBT, PAR, HNBR, EPDM, PTFE, PPSU, PET
Top side 50 mm 1.97"
Judgment output/alarm output NPN/PNP open collector (selectable), 30 VDC max., 50 mA max. for each Residual voltage: 2 V max. for NPN, 2.5 V max. for PNP, N.O./N.C. switchable
Resolution 1 mm 0.04"
Power voltage 10 to 30 VDC, ripple (P-P) 10% included, Class 2 or LPS
Enclosure rating IP67
Liquid end materials Sheath: PFA Probe: SUS304 (do not connect this directly)