| Weight | 0.085 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | FT-50AW |
| Type | DIN-rail mounting type |
| Power voltage | 12 to 24 VDC, Ripple (P-P)10% max. |
| Eco mode | 1150 mW (For 12 V), 1350 mW (For 24 V) |
| Display method | 4 + 1/two-digit 7-segment LED, dual-display (red/green) display (character height in the upper display (red): 8 mm 0.31" , character height in the lower display (green): 5.7 mm 0.22" ), Display updating cycle: 10/s |
| Operation indicator | Red LED x 3 (control output1/control output2/timing input indicator) |
| Display resolution | 0.2°F or 1.8°F (0.1°C or 1°C) (when using H10/H20/H30), 1.8°F (1°C) (when using H50/H40K/H50K) |
| Hysteresis | Variable |
| Response speed | HSP, 30, 100, 200, 500, 1000, or 5000 ms can be selected (In HSP: 15 ms max.) |
| Bank selection | Pink and Purple wires can be configured for Bank Inputs #1,2 respectively for up to 4 total banks. |
| Bank specifications | Emissivity (valid in temperature mode) and limit settings x 2 can be set for each bank. |
| Bank input | Input time: 20 ms min. |
| Control output | NPN open collector x 2 channels (N.O./N.C. selectable), 100 mA max. 40 VDC max., residual voltage: 1 V max. |
| Analog output | 4 to 20 mA, maximum load resistance: 260 Ω The upper- and lower-limit values of the analog output range can be set optionally. |
| Relative humidity | 35 to 85%, No condensation |
| Vibration resistance | 10 to 55 Hz, double amplitude: 1.5 mm 0.06" , 2 hours in each of X, Y, and Z axis directions |
| Material | Main unit, Cover: Polycarbonate, Keycaps: Polyester elastomer, Cable: Vinyl chloride Mounting bracket: SPCC |
| Accessory | DIN anchoring fixture, power cable, unit cover sticker |
| Normal | 1400 mW (For 12 V), 1600 mW (For 24 V) |
| Timing input | Input time: 2 ms min. |
| Ambient temperature | -14 to +122°F (-10 to +50°C), No freezing *1 |