| Weight | 0.15 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | GP-M001 |
| Rated pressure | -14.50 to +14.50 PSI (-100 to +100 kPa) |
| Possible display range | -17.40 to +17.40 PSI (-120.0 to +120.0 kPa) |
| Zero-cut pressure value | ±0.5% of F.S. |
| Burst pressure | 217.5 PSI (1500 kPa) |
| MPa | None |
| PSI | 0.01 |
| bar | 0.001 |
| Fluid type | Gas or liquid that will not corrode the liquid contact part |
| Type of pressure | Gage pressure |
| Precision | ±1.0% of F.S. or less *1 |
| Repeatability | ±0.3% of F.S. or less *2 |
| Temperature characteristics | ±0.6% of F.S./10°C 50°F |
| Connection port | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) |
| Box rotation angle | Maximum 330° |
| Medium temperature | -20 to +100°C -4°F to +212°F (no freezing/condensation) *3 |
| Power voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS |
| Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load) *4 |
| Display method | 4 column, digital LED, red/Vertical inversion display possible |
| Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) |
| Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) |
| Analog output | 4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V) *5 |
| Output 2 replacement type | Control output |
| Pressure resistance | 400 kPa (4 bar) |
| Ambient temperature | -20 to +80 °C -4 to 176 °F (No freezing and no condensation) |
| Relative humidity | 35 to 85 % RH (No condensation) |
| Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis) |
| Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) |
| Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. |
| Applicable cable | M12 connector 4 pin |
| kPa | 0.1 |
| Control output | Selectable from 3 to 5000 ms |
| Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
| Enclosure rating | IP67 |
| Wetted part | Pressure port: SUSXM7, Diaphragm pressure port: Al 2 O 3 (Alumina), O ring: FKM |