Product type: MP-FEA1

Energy Monitor Main Unit

  • Process Controls / Process Sensors
  • Flow Sensors / Flow Meters
  • Air Quality Multi-Sensor
  • Models
  • Energy Monitor Main Unit
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.11 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)
EAN code
Product group
Model MP-FEA1
Number of measurement circuits 1 (up to 2 circuits with the 1-phase 2-wire setting *1 )
Over current withstand capability 1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less)
1-phase 3-wire ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)
3-phase 3-wire ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 173 to 240 VAC (L-L)
3-phase 4-wire ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N), 173 to 480 VAC (L-L) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 173 to 415 VAC (L-L)
Maximum permissible voltage to earth ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth ・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth
Input voltage fluctuation range −15% to +15% of the rated input voltage
Rated input frequency 50/60 Hz
Current ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±0.5% of F.S. *3
Active power/reactive power/apparent power -8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA]
Active energy/reactive energy/apparent energy 0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh]
Power factor (PF) ±0.01 *3
Frequency 0.0 to 90.0 [Hz], display resolution 0.1 [Hz]
Active energy ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3 Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%) ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3
Reactive energy ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3 Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%) Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%) Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%) ・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3
Apparent energy ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3 ・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4
Effect of ambient temperature ±0.03%/K *3 *5
Effect of harmonics ±0.5% of RD *3 *6
Power ±0.1 [Hz] *3
Current consumption 36 mA
Withstand voltage Across all terminals and housing: 2500 VAC for 1 minute Across voltage measurement terminal and communication terminal: 2500 VAC for 1 minute Across CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute
Insulation resistance Across all terminals and housing: 20 MΩ min. (500 VDC) Across voltage measurement terminal and CT input terminal and across communication terminal: 20 MΩ min. (500 VDC)
Relative humidity 35%RH to 85%RH (no condensation)
Measurement category II
Altitude 2500 m or less
Pollution degree 2
Mounting method DIN rail mounting
Vibration resistance 10 to 500 Hz, power spectral concentration: 0.033G 2 /Hz, XYZ axes
Shock resistance 150 m/s 2 , 2 times each for X, Y, and Z axes
Material Polycarbonate
Electrical service type 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)
Primary-side rated current, In When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2 When using specialized CT MP-FEC50M: 50 A When using specialized CT MP-FEC100M: 100 A
1-phase 2-wire ・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N) ・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N)
Voltage ±0.5% of RD (within rated input voltage) *3
Ambient temperature -5 to +55°C 23 to 131°F (no freezing)