| Weight | 1.2 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | SJ-F700 |
| Voltage application method | Variable DC |
| Applied voltage | ±8200 V max. |
| Ion balance control method | Multi-I.C.C |
| Ion balance | When using SJ-FB01: ±1 V *1 *2 When not using SJ-FB01: ±3 V *1 *2 |
| Static elimination time | Approx. 0.5 s *3 *2 |
| Installation distance | 50 mm 1.97" or more |
| Maximum air volume | 4.8 m 3 /min 169.51 ft 3 /min |
| Ozone density | 0.005 ppm or less |
| Sampling cycle | 0.1 s |
| Data history | Data saved every hour |
| Event log | Saved events: Errors, Warnings, Charge level threshold exceeded, Ion balance threshold exceeded, Static elimination start/stop, Power ON/OFF, Clean operation Charge level/ion balance outside threshold/event triggered when: Data stored for 30 seconds before and 30 seconds after an event |
| Other functions | Auto-clean, Sensor feedback |
| IN2 | Clean input |
| IN3 | Event trigger input |
| Output | Photo MOS relay output, N.O./N.C. switchable, Maximum rating: 26.4 V (50 mA), Residual voltage when ON: 1 V or less |
| Functions | Assignable functions: Static elimination status, Ion level alarm, Condition alarm, Fan rotation speed alarm, Charge level threshold exceeded, System error, Other error, Installation error alarm, Ion balance threshold exceeded, Charged object detection, Feedback sensor error *5 |
| Connector | RJ-45 8-pin connector |
| Current consumption | Normal (including input/output load): 1.6 A or less Normal (excluding input/output load): 1.45 A or less ECO mode: 0.18 A (typical) *6 |
| Relative humidity | 35 to 85% RH (no condensation) |
| Overvoltage category | I |
| Pollution degree | 2 |
| Material | Case: PC / ABS *7 , Front ventilation guard: SUS, Rear suction guard: SUS, Louvers: PC / ABS *7 , Display sheet: PC, Operation buttons: PC, Mounting adapter insulation rubber: Silicone rubber, Bottom insulation rubber: Polyurethane, Mounting fixture: PBT, Terminal block: LCP, Ethernet connector: Brass (tin plated), AC adapter connector: PBT, Attached screws: Iron (trivalent chromate) |
| Items | Date/time, Ion level, Electrostatic charge level, Air flow, Unit status, Various threshold values, Ion balance, Temperature, Humidity *4 |
| Number of outputs | 3 (OUT1 to OUT3) |
| Standard | 100BASE-TX |
| Power voltage | 24 VDC ±10% or dedicated AC adapter (OP-88766) |
| Ambient temperature | 0 to +40°C 32 to +104°F (0 to +45°C 32 to +113°F when using OP-88767 or OP-88768) |