Product AttributeAttribute Value
Weight1.6 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)
EAN code
Product group
Model SV2-100L2
Control circuit 0.2 Arms
Overvoltage category III
Control mode Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method
Feedback 22-bit serial encoder (absolute) communication, fully closed control serial communication, analog feedback
Pollution degree Pollution degree: 2 (in an IP54 or higher control panel) However, usage under the following requirements required: • No corrosive gas or flammable gas present • No exposure to water, oil, or chemicals • No dust present
Operating ambient temperature -5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more)
Storage ambient temperature -20 to +85°C -4 to +185°F (no freezing)
Operating/storage ambient temperature 95% RH or less (no condensation)
Altitude 2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more)
Vibration resistance 4.9 m/s 2 16.1'/s 2 (JIS C60068-2-6 compliant)
Impact resistance 19.6 m/s 2 64.3'/s 2 ( JIS C60068-2-27 compliant)
Other No static electricity noise, strong electric fields, magnetic fields, or radiation present
Min insulation resistance 500 VDC, 1 MΩ or more with insulation resistance tester
EMI EN55011 Class A, EN61800-3, EN61000-6-4
EMS EN61800-3, EN61000-6-2
North America EMI standard FCC Part15 B, ICES-003. Class A
Safety function STO function (STO/EN61800-5-2)
Response time 8 ms (max.)
Input STO1, STO2: Base block signal for power module Internal impedance: 4.7 kΩ Operable voltage range: +24 V ±20% Max. delay time: 8 ms (Time from turning STO1, STO2 off until motor current cutoff)
Output EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 8 ms (Time from changing STO1, STO2 until EDM change)
Applied standard EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1
Protection function Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc.
Insulation withstand voltage 1500 VAC or more (between primary side and ground) 3000 VAC or more (between primary side and secondary side) 350 VAC: Between secondary circuit and ground
Max applicable motor capacity 1.0 kW
Power supply capacity for 1 amplifier Three-phase 200 V: 2.3 kVA
Max 17 Arms
Main circuit power loss 53.6 W
Regenerative resistor power loss 8 W
Control circuit power loss 17 W
Total power loss 78.6 W
At main circuit voltage change 0% with ±10% of rated voltage (at rated rotation speed)
At ambient temperature change ±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed)
Torque control accuracy (reproducibility) ±1%
Speed frequency response frequency 2.6 kHz
Dynamic brake Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP)
Regenerative resistor Built-in regenerative resistor: 50 W to 400 W ... not installed 750 W to 5.0 kW ... installed External regenerative resistor: OP-84399 (50 W to 1.0 kW) OP-87073 (1.5 kW *2 )
Status display LED CHARGE: For notification of main circuit power supply input (orange) POWER: For notification of control circuit power supply input (green) CONNECT: For notification of connection (green) LINK1, LINK2: For notification of MECHATROLINK communication (green)
Auxiliary function Gain control, alarm history, Z-phase search, etc.
Max input voltage 28.8 VDC
Rated input voltage 24 VDC
Min ON voltage 19 VDC
Min OFF current/voltage High-speed input: 0.6 mA, general input: 0.3 mA
Common point mode Independent common
Input time constant 250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms
Input current High-speed input: 4.5 mA, general input: 3.7 mA
Input impedance 30 kΩ
Assignable input signals Full signal assignment, logic-settable forced stop (FSTOP), external latch signals 1 to 3 (EXT1, EXT2, EXT3), origin return deceleration switch (DEC), forward limit switch (LSP), reverse limit switch (LSN), forward torque limit selection (PTL), reverse torque limit selection (NTL)
Output mode Transistor NPN output
Rated load 30 VDC / 50 mA
Leakage current when OFF 0.1 mA
Residual voltage when ON 1.5 VDC or less
Assignable output signals Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), in position (INPOS), speed matching (VCMP), zero speed detection (ZSP), operation preparation complete (RDY), torque limiting (TLM), speed limiting (VLM), electromagnetic brake timing (BRAKE), warning (WARN), Positioning proximity (NEAR)
Accuracy ±1% of F.S.
Resolution 16 bits
Line driver SN75ALS174 (T.I.) or equivalent
Output frequency 1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3
Output range ±10 V (linearity valid range ±8 V)
Conversion precision ±20 mV (typ.)
Max allowable load current ±10 mA
Conversion speed 1.2 ms (typ.)
Station address 03H to EFH (Max. number of connectable slaves: 62)
Transmission speed 100 Mbps
Transmission frequency 125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms)
Communication cycle Support for values starting at transmission frequency × 1
Number of transmitted bytes 32 bytes/station, 48 bytes/station (selectable with slide switch)
Transmission media/cable Category 5e-compliant, STP cross cable
Operating specifications Position control / speed control / torque control
Command input MECHATROLINK-III command (sequence, motion, monitor, adjustment, etc.)
Max transmission distance 50 m 164.0' *4
Communication standard USB 2.0-compliant
Function Status display, parameter setting, tuning, etc.
Capacity 1.0 kW
Main circuit/control circuit No more than ±5%
UL/CSA standards UL61800-5-1, CSA22.2 No.274
Low-voltage directive EN61800-5-1, EN50178
Type Attached to base mount
Safety parameters SIL3/EN61508, SIL CL 3/EN62061, PLe (Category3) / EN ISO13849-1: 2008
Main circuit power supply Three-phase 200 V
Continuous 7.6 Arms
Main circuit 34 A
At load fluctuation ±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed)
Panel function 7-segment LED Rotary switch ×2 (16 ch) Slide switch ×1 (4 ch)
Number of outputs 4
Max input voltage ±12 V
Output mode Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output
No of channels 2 ch
Connected device PC