Product type: SV2-200L2
Three-phase AC200 to 240V for 2kW
| Thomas Hoffmann |
| +49 305 201 4443 |
| sales@zwodltd.com |
| Price: Please send request |
| Request Lead Time: app. 1 Day |
| Delivery Time: by agreement Estimated delivery time to our warehouse in Berlin |
| Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2025 |
| Product Attribute | Attribute Value |
|---|---|
| Weight | 2.7 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | SV2-200L2 |
| Control circuit | 0.25 Arms |
| Overvoltage category | III |
| Control mode | Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
| Feedback | 22-bit serial encoder (absolute) communication, fully closed control serial communication, analog feedback |
| Pollution degree | Pollution degree: 2 (in an IP54 or higher control panel) However, usage under the following requirements required: • No corrosive gas or flammable gas present • No exposure to water, oil, or chemicals • No dust present |
| Operating ambient temperature | -5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more) |
| Storage ambient temperature | -20 to +85°C -4 to +185°F (no freezing) |
| Operating/storage ambient temperature | 95% RH or less (no condensation) |
| Altitude | 2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more) |
| Vibration resistance | 4.9 m/s 2 16.1'/s 2 (JIS C60068-2-6 compliant) |
| Impact resistance | 19.6 m/s 2 64.3'/s 2 ( JIS C60068-2-27 compliant) |
| Other | No static electricity noise, strong electric fields, magnetic fields, or radiation present |
| Min insulation resistance | 500 VDC, 1 MΩ or more with insulation resistance tester |
| EMI | EN55011 Class A, EN61800-3, EN61000-6-4 |
| EMS | EN61800-3, EN61000-6-2 |
| North America EMI standard | FCC Part15 B, ICES-003. Class A |
| Safety function | STO function (STO/EN61800-5-2) |
| Response time | 8 ms (max.) |
| Input | STO1, STO2: Base block signal for power module Internal impedance: 4.7 kΩ Operable voltage range: +24 V ±20% Max. delay time: 8 ms (Time from turning STO1, STO2 off until motor current cutoff) |
| Output | EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 8 ms (Time from changing STO1, STO2 until EDM change) |
| Applied standard | EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1 |
| Protection function | Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc. |
| Insulation withstand voltage | 1500 VAC or more (between primary side and ground) 3000 VAC or more (between primary side and secondary side) 350 VAC: Between secondary circuit and ground |
| Max applicable motor capacity | 2.0 kW |
| Power supply capacity for 1 amplifier | Three-phase 200 V: 4 kVA |
| Max | 42 Arms |
| Main circuit power loss | 111.9 W |
| Regenerative resistor power loss | 16 W |
| Control circuit power loss | 22 W |
| Total power loss | 149.9 W |
| At main circuit voltage change | 0% with ±10% of rated voltage (at rated rotation speed) |
| At ambient temperature change | ±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed) |
| Torque control accuracy (reproducibility) | ±1% |
| Speed frequency response frequency | 2.6 kHz |
| Dynamic brake | Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
| Regenerative resistor | Built-in regenerative resistor: 50 W to 400 W ... not installed 750 W to 5.0 kW ... installed External regenerative resistor: OP-84399 (50 W to 1.0 kW) OP-87073 (1.5 kW *2 ) |
| Status display LED | CHARGE: For notification of main circuit power supply input (orange) POWER: For notification of control circuit power supply input (green) CONNECT: For notification of connection (green) LINK1, LINK2: For notification of MECHATROLINK communication (green) |
| Auxiliary function | Gain control, alarm history, Z-phase search, etc. |
| Max input voltage | 28.8 VDC |
| Rated input voltage | 24 VDC |
| Min ON voltage | 19 VDC |
| Min OFF current/voltage | High-speed input: 0.6 mA, general input: 0.3 mA |
| Common point mode | Independent common |
| Input time constant | 250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
| Input current | High-speed input: 4.5 mA, general input: 3.7 mA |
| Input impedance | 30 kΩ |
| Assignable input signals | Full signal assignment, logic-settable forced stop (FSTOP), external latch signals 1 to 3 (EXT1, EXT2, EXT3), origin return deceleration switch (DEC), forward limit switch (LSP), reverse limit switch (LSN), forward torque limit selection (PTL), reverse torque limit selection (NTL) |
| Output mode | Transistor NPN output |
| Rated load | 30 VDC / 50 mA |
| Leakage current when OFF | 0.1 mA |
| Residual voltage when ON | 1.5 VDC or less |
| Assignable output signals | Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), in position (INPOS), speed matching (VCMP), zero speed detection (ZSP), operation preparation complete (RDY), torque limiting (TLM), speed limiting (VLM), electromagnetic brake timing (BRAKE), warning (WARN), Positioning proximity (NEAR) |
| Accuracy | ±1% of F.S. |
| Resolution | 16 bits |
| Line driver | SN75ALS174 (T.I.) or equivalent |
| Output frequency | 1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3 |
| Output range | ±10 V (linearity valid range ±8 V) |
| Conversion precision | ±20 mV (typ.) |
| Max allowable load current | ±10 mA |
| Conversion speed | 1.2 ms (typ.) |
| Station address | 03H to EFH (Max. number of connectable slaves: 62) |
| Transmission speed | 100 Mbps |
| Transmission frequency | 125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
| Communication cycle | Support for values starting at transmission frequency × 1 |
| Number of transmitted bytes | 32 bytes/station, 48 bytes/station (selectable with slide switch) |
| Transmission media/cable | Category 5e-compliant, STP cross cable |
| Operating specifications | Position control / speed control / torque control |
| Command input | MECHATROLINK-III command (sequence, motion, monitor, adjustment, etc.) |
| Max transmission distance | 50 m 164.0' *4 |
| Communication standard | USB 2.0-compliant |
| Function | Status display, parameter setting, tuning, etc. |
| Capacity | 2.0 kW |
| Main circuit/control circuit | No more than ±5% |
| UL/CSA standards | UL61800-5-1, CSA22.2 No.274 |
| Low-voltage directive | EN61800-5-1, EN50178 |
| Type | Attached to base mount |
| Safety parameters | SIL3/EN61508, SIL CL 3/EN62061, PLe (Category3) / EN ISO13849-1: 2008 |
| Main circuit power supply | Three-phase 200 V |
| Continuous | 18.5 Arms |
| Main circuit | 34 A |
| At load fluctuation | ±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
| Panel function | 7-segment LED Rotary switch ×2 (16 ch) Slide switch ×1 (4 ch) |
| Number of outputs | 4 |
| Max input voltage | ±12 V |
| Output mode | Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output |
| No of channels | 2 ch |
| Connected device | PC |