Product type: SV3-100L2
3-phase 200 to 240 VAC For 1 kW motors
| Thomas Hoffmann |
| +49 305 201 4443 |
| sales@zwodltd.com |
| Price: Please send request |
| Request Lead Time: app. 1 Day |
| Delivery Time: by agreement Estimated delivery time to our warehouse in Berlin |
| Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2025 |
| Product Attribute | Attribute Value |
|---|---|
| Weight | 1.6 KG / psc. |
| Commodity number | |
| Country of origin | |
| Dimensions (WxHxD) | |
| EAN code | |
| Product group | |
| Model | SV3-100L2 |
| Control circuit | 0.2 Arms |
| Overvoltage category | III |
| Control mode | Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system |
| Feedback | Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback |
| Pollution degree | 2 (in an IP54 or higher control panel) However, the product must be used in the following environments: • No corrosive or flammable gases • No exposure to water, oil, or chemicals • No dust |
| Operating ambient temperature | -5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher) |
| Storage ambient temperature | -20 to +85°C -4 to +185°F (No freezing) |
| Operating/storage ambient temperature | 95% RH or less (No condensation) |
| Altitude | No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher) |
| Vibration resistance | 4.9 m/s 2 16.1 ft/s 2 (Compliant with JIS C60068-2-6) |
| Impact resistance | 19.6 m/s 2 64.3 ft/s 2 (Compliant with JIS C60068-2-27) |
| Other | No static noise, strong electric or magnetic fields, or radiation |
| EMI | EN55011 Class A, EN61800-3, EN61000-6-4 |
| EMS | EN61800-3, EN61000-6-2 |
| North America EMI standard | FCC Part 15 B, ICES-003. Class A |
| Safety function | STO function (STO/EN 61800-5-2) |
| Response time | 4 ms(max) |
| Input | STO1, STO2: Power module base block signals Internal impedance: 5.1 kΩ Operable voltage range: +24 V, ±20% Max. delay time: 4 ms (Time from when STO1 and STO2 are turned off until motor current is interrupted) |
| Output | EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 4 ms (Time from STO1 and STO2 change to EDM change) |
| Protection function | Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc. |
| Min insulation resistance | 500 VDC 1 MΩ or more with insulation resistance meter |
| Insulation withstand voltage | 1,500 VAC or more (between primary side and ground) 3,000 VAC or more (between primary and secondary) 350 VAC: between secondary circuit and ground |
| Max applicable motor capacity | 1.0 kW |
| Power supply capacity for 1 amplifier | 2.3 kVA |
| Max | 17 Arms |
| Main circuit power loss | Three-phase 200 V: 49.2 W DC 270 V: 38.7 W |
| Regenerative resistor power loss | Three-phase 200 V: 15 W DC 270 V: ― |
| Control circuit power loss | 14 W |
| Total power loss | Three-phase 200 V: 63.2 W DC 270 V: 52.7 W |
| At main circuit voltage change | Rated voltage ±10%: 0% (at rated rotation speed) |
| At ambient temperature change | Ambient temperature 0 to +50°C 32 to 122°F : ±0.1% or less (at rated rotation speed) |
| Torque control accuracy (reproducibility) | ±1% |
| Velocity frequency response | 3.1 kHz |
| Dynamic brake | Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP) |
| Regenerative resistor | Built-in regenerative resistor: Disabled at 50 to 400 W Enabled at 750 W to 5.0 kW External regenerative resistor: OP-84399 (50 W to 1.0 kW) OP-87073 (1.5 kW *4 ) |
| Communication status indicator LED | EtherCAT® communication: L/A × 2 EtherCAT® communication status: RUN×1 EtherCAT® error status: ERR×1 |
| Monitor | Lifespan prediction, vibration, load factor, power consumption, temperature, etc. |
| Max input voltage | 28.8 VDC |
| Rated input voltage | 24 VDC |
| Min ON voltage | 19 VDC |
| Max OFF current/voltage | High-speed input: 0.1 mA, General-purpose input: 0.3 mA |
| Common point mode | Independent common |
| Input time constant | 250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
| Input current | High-speed input: 4.4 mA, General-purpose input: 4.5 mA |
| Input impedance | 30 kΩ |
| Assignable input signals | All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL) |
| Output mode | Transistor NPN output |
| Rated load | 30 VDC/50 mA |
| Leakage current when OFF | 0.5 mA |
| Residual voltage when ON | 1.5 VDC or less |
| Assignable output signals | Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR) |
| Accuracy | ±1% of F.S. |
| Resolution | 16 bits |
| Line driver | SN75ALS174 (T.I.) equivalent |
| Output frequency | 1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz) *5 |
| Output range | ±10 V (Linearity effective range: ±8 V) |
| Conversion precision | ±20 mV (typ.) |
| Max allowable load current | ±10 mA |
| Conversion speed | 1.2 ms (typ.) |
| Physical layer | 100 BASE-TX(IEEE802.3) |
| Cable | Category 5 STP, 2 pair Automatic cable identification is performed by the AUTO MDI/MDI-X function. |
| Mailbox | Emergency messages, SDO requests, SDO responses |
| Distributed clocks | Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments) |
| Max distance between stations | 50 m 164.0' |
| Communication standard | USB 2.0–compliant |
| Function | Status display, Parameter settings, Tuning, etc. |
| Capacity | 1.0 kW |
| Main circuit/control circuit | ±5% max. |
| UL/CSA standards | UL 61800-5-1, CSA 22.2 No. 274 |
| Machinery Directive | EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3 |
| Type | Base mount installation |
| Safety parameters | SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015 |
| Main circuit power supply | Three-phase 200 V/DC 270 V |
| Continuous | 7.6 Arms |
| Main circuit | 34 A *3 |
| At load fluctuation | 0 to 100% load variation: ±0.01% or less (at rated rotation speed) |
| Panel function | 7-segment LED Two rotary switches (16 ch) |
| Tuning | Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc. |
| Number of outputs | 4 |
| Max input voltage | ±12 V |
| Output mode | A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output |
| No of channels | 2 ch |
| Connected device | PC |