KEYENCE

SV3-150L2

Product type: SV3-150L2

3-phase 200 to 240 VAC For 1.5 kW motors

  • Controls
  • Servo Motors / Servo Systems
  • Servo System
  • Models
  • 3-phase 200 to 240 VAC For 1.5 kW motors
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight2.1 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)
EAN code
Product group
Model SV3-150L2
Control circuit 0.2 Arms
Overvoltage category III
Control mode Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system
Feedback Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback
Pollution degree 2 (in an IP54 or higher control panel) However, the product must be used in the following environments: • No corrosive or flammable gases • No exposure to water, oil, or chemicals • No dust
Operating ambient temperature -5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)
Storage ambient temperature -20 to +85°C -4 to +185°F (No freezing)
Operating/storage ambient temperature 95% RH or less (No condensation)
Altitude No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)
Vibration resistance 4.9 m/s 2 16.1 ft/s 2 (Compliant with JIS C60068-2-6)
Impact resistance 19.6 m/s 2 64.3 ft/s 2 (Compliant with JIS C60068-2-27)
Other No static noise, strong electric or magnetic fields, or radiation
EMI EN55011 Class A, EN61800-3, EN61000-6-4
EMS EN61800-3, EN61000-6-2
North America EMI standard FCC Part 15 B, ICES-003. Class A
Safety function STO function (STO/EN 61800-5-2)
Response time 4 ms(max)
Input STO1, STO2: Power module base block signals Internal impedance: 5.1 kΩ Operable voltage range: +24 V, ±20% Max. delay time: 4 ms (Time from when STO1 and STO2 are turned off until motor current is interrupted)
Output EDM: Built-in safety circuit status monitoring (fixed output) Max. allowable voltage: 30 VDC Max. allowable current: 50 mA DC Max. voltage drop at ON: 1.5 V Max. delay time: 4 ms (Time from STO1 and STO2 change to EDM change)
Protection function Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.
Min insulation resistance 500 VDC 1 MΩ or more with insulation resistance meter
Insulation withstand voltage 1,500 VAC or more (between primary side and ground) 3,000 VAC or more (between primary and secondary) 350 VAC: between secondary circuit and ground
Max applicable motor capacity 1.5 kW
Power supply capacity for 1 amplifier 3.2 kVA
Max 28 Arms
Main circuit power loss Three-phase 200 V: 72.6 W DC 270 V: 55.8 W
Regenerative resistor power loss Three-phase 200 V: 30 W DC 270 V: ―
Control circuit power loss 15 W
Total power loss Three-phase 200 V: 87.6 W DC 270 V: 70.8 W
At main circuit voltage change Rated voltage ±10%: 0% (at rated rotation speed)
At ambient temperature change Ambient temperature 0 to +50°C 32 to 122°F : ±0.1% or less (at rated rotation speed)
Torque control accuracy (reproducibility) ±1%
Velocity frequency response 3.1 kHz
Dynamic brake Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)
Regenerative resistor Built-in regenerative resistor: Disabled at 50 to 400 W Enabled at 750 W to 5.0 kW External regenerative resistor: OP-84399 (50 W to 1.0 kW) OP-87073 (1.5 kW *4 )
Communication status indicator LED EtherCAT® communication: L/A × 2 EtherCAT® communication status: RUN×1 EtherCAT® error status: ERR×1
Monitor Lifespan prediction, vibration, load factor, power consumption, temperature, etc.
Max input voltage 28.8 VDC
Rated input voltage 24 VDC
Min ON voltage 19 VDC
Max OFF current/voltage High-speed input: 0.1 mA, General-purpose input: 0.3 mA
Common point mode Independent common
Input time constant 250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms
Input current High-speed input: 4.4 mA, General-purpose input: 4.5 mA
Input impedance 30 kΩ
Assignable input signals All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)
Output mode Transistor NPN output
Rated load 30 VDC/50 mA
Leakage current when OFF 0.5 mA
Residual voltage when ON 1.5 VDC or less
Assignable output signals Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)
Accuracy ±1% of F.S.
Resolution 16 bits
Line driver SN75ALS174 (T.I.) equivalent
Output frequency 1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz) *5
Output range ±10 V (Linearity effective range: ±8 V)
Conversion precision ±20 mV (typ.)
Max allowable load current ±10 mA
Conversion speed 1.2 ms (typ.)
Physical layer 100 BASE-TX(IEEE802.3)
Cable Category 5 STP, 2 pair Automatic cable identification is performed by the AUTO MDI/MDI-X function.
Mailbox Emergency messages, SDO requests, SDO responses
Distributed clocks Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)
Max distance between stations 50 m 164.0'
Communication standard USB 2.0–compliant
Function Status display, Parameter settings, Tuning, etc.
Capacity 1.5 kW
Main circuit/control circuit ±5% max.
UL/CSA standards UL 61800-5-1, CSA 22.2 No. 274
Machinery Directive EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3
Type Base mount installation
Safety parameters SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015
Main circuit power supply Three-phase 200 V/DC 270 V
Continuous 11.6 Arms
Main circuit 34 A *3
At load fluctuation 0 to 100% load variation: ±0.01% or less (at rated rotation speed)
Panel function 7-segment LED Two rotary switches (16 ch)
Tuning Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.
Number of outputs 4
Max input voltage ±12 V
Output mode A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output
No of channels 2 ch
Connected device PC