Pilz

315185

Product type: PSSu E F PS-P-R

Description

PSSu, electronic module, failsafe, supply voltage, infeed periphery supply 24 V DC 10 A, infeed C-rail 10 A, for railway applications.
  • Controller
  • I/O systems
  • PSSuniversal - I/O modules
  • PSSuniversal - power supply modules
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-3 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.035 KG / psc.
Commodity number85044090
Country of originDE
Dimensions (WxHxD)12.6x76x60.2 mm
EAN code
Product group7017
approval CE UKCA TÜV
etim version ETIM-7.0
gross weight 40
purpose of u2 Periphery Supply
eclass version ECLASS-9.1
terminal style steckbar
tolerance of u2 -30 %/+25 %
application range Standard/Fail-safe
ambient temperature -40
broad band noise to EN 61373
emc to standard ... EN 61000-4-4 EN 61000-6-2 EN 61000-4-5 EN 61000-4-6 EN 61000-6-4 EN 61000-4-2 EN 61000-4-3
etim reference group EG000024
overvoltage category OV2
supply voltage 2 (v) 24
housing material code PA
name of coding element A
acc. shock to standard1 2g
acc. shock to standard2 5g
colour of coding element gelb
eclass reference feature 27242611
protection type standard EN 60529
protection type, housing IP20
protection type, mounting IP51
type of supply voltage u2 DC
vibration to standard ... EN 50125-3
perm. operating height asl 2000 m
pot. isolation uint1 to u2 3050 V
ambient temp. to standard 2 -40 ... +70 °C
ambient temp. to standard 3 -40 ... +70 °C
app. site standard1 railway EN 50125-3
app. site standard2 railway EN 61373
climatic suitability to ... EN 50125-1 EN 60068-2-2 EN 60068-2-1 EN 50155 EN 60068-2-14 EN 50125-3
freq. broadband noise, rail 5 ... 150 Hz
accel. broadband noise, rail 0,79 g RMS
ambient temperature standard EN 50155
housing material front plate PC
standard 2 for ambient temp. EN 50125-1
standard 3 for ambient temp. EN 50125-3
standard1 b/band noise, rail EN 61373
clearance & creepage dist. to EN 50124-1
weee classifikation (08/2018) 5 devices (feed size < 50cm)
app. site to standard1 railway Gleisbereich (1m - 3m)
app. site to standard2 railway Kategorie 1, Klasse A + B
housing material lower section PC
pollution degree clear.&creep. PD2