Description

Magnetic safety switch 2 n/o, 1 auxiliary contact n/o, cylindrical design M12, with 10 m cable, LED, IP67/69, operating distance dependingon the actuator 8/12 mm, for applications with PSEN ix1, PU = 1 sensor without actuator, stainless steel housing, certification (ATEX, CE, EAC, ECOLAB, TÜV, UL/cUL).
  • Sensor technology
  • Safety switches
  • PSENmag - non-contact, magnetic safety switches
  • PSENmag for electronic/electromechanic relays
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-3 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.22 KG / psc.
Commodity number
Country of origin
Dimensions (WxHxD)12x12x76 mm
EAN code
Product group7045
approval IEC Ex CE UL/cUL ATEX KCs EAC (Eurasian) ECOLAB TÜV
unit type Sensor
cable lines Li9Y11Y 6 x 0.14 mm2
etim version ETIM-7.0
gross weight 230 g
eclass version ECLASS-9.1
rohs directive 2011/65/EU 2015/863/EU
connection type 10 m cable
humidity rating 90 % r. h. at 40 °C
rohs conformity yes
rohs exceptions no
type 1 actuator PSEN ma1.3-08 EX VA
reach compliance Contains no SVHC substances
sensor principle magnetic
atex category gas Ex II 3G Ex mc IIC T6 Gc
switching voltage 24 V
ul enclosure type Type 1
atex category dust Ex II 3D Ex mc IIIC T80°C Dc
supply voltage (v) 24 V
ambient temperature -25 - 55 °C
emc to standard ... EN 60947-5-3
etim reference group EG000026
acc. shock to standard1 30g
atex application area x X: -25°C ≤ ta ≤ +55°C
atex certificate number SEV 17 ATEX 0155 X
eclass reference feature 27272402
coding level to iso 14119 Low
type of supply voltage u1 DC
vibration to standard ... EN 60947-5-2
perm. operating height asl 4000 m
housing material upper part Stainless steel 1.4401
sensor can be flush-mounted Yes, follow installation guide
climatic suitability standard IEC 60068-2-30
weee classifikation (08/2018) 5 devices (feed size < 50cm)
classification to en 60947-5-3 PDDB
pollution degree clear.&creep. 3
suitable for series connection yes
utilisation cat. reed contacts DC-12