Pilz

541353

Product type: PSEN cs3.19n 1 switch

Description

RFiD safety switch 2 safe SC outputs, 5-pin M12 male connector, one actuation direction, IP67, switching distance 11 mm, Sao = 8 mm, Sar= 20 mm, PU = 1 piece coded switch without actuator.
  • Sensor technology
  • Safety switches
  • PSENcode - non-contact, coded safety switches
  • PSENcode - compact design
  • PSEN cs3.19n 1 switch
Contact Person
Thomas Hoffmann
+49 305 201 4443
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-3 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.04 KG / psc.
Commodity number85365019
Country of originCH
Dimensions (WxHxD)26x37x18 mm
EAN code
Product group7046
cas no. 7439-92-1 1317-36-8
approval CE cULus Listed FCC IC EAC (Eurasian) TÜV
unit type Sensor
cable lines Li9Y11Y 8 x 0.14 mm2
etim version ETIM-7.0
gross weight 60
eclass version ECLASS-9.1
rohs directive 2011/65/EU 2015/863/EU
connection type M12, 5-pin male
humidity rating 93 % r. h. at 40 °C
rohs conformity yes
rohs exceptions yes
type 1 actuator PSEN cs3.19
reach compliance contains min. 1 SVHC-substance
sensor principle Transponder
supply voltage (v) 24 24
transponder coding coded
ambient temperature -25 55
emc to standard ... EN 60947-5-3
operating frequency 122 kHz - 128 kHz
etim reference group EG000026
overvoltage category III
power consumption dc 1
number of ossd outputs 2
%-part of the pollutant > 0,1%
acc. shock to standard1 30g
eclass reference feature 27272403
coding level to iso 14119 Low
potential isolation s/c o No
reach included substances Lead Lead oxide
type of supply voltage u1 DC
vibration to standard ... EN 60947-5-2
housing material upper part PBT
sensor can be flush-mounted Yes, follow installation guide
ambient temperature standard EN 60068-2-14
bend radius (when laying) k1 5 x Ø
change op. dist. temp.change +-0.01mm/°C
storage temperature standard EN 60068-2-1/-2
climatic suitability standard EN 60068-2-78
rohs except.s acc. to direct. 7a 7c I
weee classifikation (08/2018) 5 devices (feed size < 50cm)
classification to en 60947-5-3 PDDB
pollution degree clear.&creep. 3
s/c output short circuit proof Yes
suitable for series connection no
utilisation cat. to en 60947-1 DC-12