• sort By
  • per page
CompareProductAvailability / Price
up to 5 items.
B924634
BENDER
ESL0107/280
Part number #: B924634
Single Phase TransFormer 280VA AC230/23-28V
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B916612
BENDER
UG140P
Part number #: B916612
Earth Fault Relayr Un:DC 110 V Us: DC 110 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065003
BENDER
IRDH375-415
Part number #: B91065003
insulations Monitoring Device Un:3(N)AC 0-793 V/ DC 0-650 V Us: AC 20-460 Hz, 400 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93060002
BENDER
CME420-D-2
Part number #: B93060002
Current Monitor Ian:AC 42...460HZ 0,1...16 A Us: DC / AC 15-460 Hz, 70..300 V quick-blow fuse 6 A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B936158
BENDER
ZUE150-U3
Part number #: B936158
Automatic-Restart-Relay Un:AC 50Hz 230V OPTION U3 Us=Un: AC 50 Hz 220 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065123
BENDER
IRDH275B-49335
Part number #: B91065123
insulations Monitoring Device Un: 3(N)AC 0-793V/DC 0-650 V Us: AC 20-460 Hz, 88-264 V/ DC 77-286 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065007
BENDER
IRDH375B-415
Part number #: B91065007
insulations Monitoring Device Un:3(N)AC 0-793 V/ DC 0-650 V Us: AC 20-460 Hz, 400 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065502
BENDER
IRDH575B1-427
Part number #: B91065502
insulations Monitoring Device Un:3(N)AC/ DC 20-575 V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91080003
BENDER
EDS460-L-1
Part number #: B91080003
insulation Fault Locator Ids:2-10 mA, Idn: AC 100 mA-10 A Us: AC 42-460 Hz, 17…72 V / DC 9,6- 94V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065702W
BENDER
isoLR-327+AGH-LR-3
Part number #: B91065702W
insulations Monitoring Device with AGH-LR-3 Un: AC 0-793V/DC 0-1100 V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B986764
BENDER
9604-1421
Part number #: B986764
120 kOhm Measuring instrument Skala: 90 Grad , I: 0-400 µA
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048014
BENDER
IR470LY2-6021
Part number #: B91048014
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: DC 9,6-84 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91023014
BENDER
IR125Y-47
Part number #: B91023014
insulations Monitoring Device Un: DC 19,2-308 V AC 19,2-265 V Us=Un: DC 19,2-308 V, AC 22-460 Hz 19,2-265 V , quick-blow fuse 6A , screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048007W
BENDER
IR470LYW-40
Part number #: B91048007W
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: AC 50-400 Hz 230 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065132W
BENDER
isoPV-327+AGH-PV
Part number #: B91065132W
insulations Monitoring Device with AGH-PV3 Un: AC 0-793V/ DC 0-1100V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B94053102
BENDER
AN110-2
Part number #: B94053102
Power Supply Un:DC 100-353V AC 50-60Hz 100-240V Us: DC 100-353 V/ AC 50-60 Hz 100-240 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048007T
BENDER
IR470LYT-40
Part number #: B91048007T
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: AC 50-400 Hz 230 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065116
BENDER
IRDH275BU-627
Part number #: B91065116
insulations Monitoring Device Un:AC0-460 Hz /DC 0-3,6 KV Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91067130
BENDER
iso685-S-P
Part number #: B91067130
Un: AC 0-690 V/DC 0-1000 V
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B98080606
BENDER
WS80x120
Part number #: B98080606
Measuring CT (split core) 80 x 120 mm for residual current monitoring systems and for insulation fault location system
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065703W
BENDER
isoLR-335+AGH-LR-3
Part number #: B91065703W
insulations Monitoring Device with AGH-LR-3 Un: AC 0-793V/DC 0-1100 V Us: AC 40-460 Hz, 88-264 V/ DC 77-286 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91016304W
BENDER
IR423-D4W-1
Part number #: B91016304W
insulations Monitoring Device Un: AC30-460 Hz 0-300 V Us: AC 42-460 Hz, 17…72 V / DC 9,6- 94V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065500W
BENDER
IRDH575B1W-435
Part number #: B91065500W
insulations Monitoring Device Un:3(N)AC/ DC 20-575 V Us: AC 40-460 Hz, 88-264 V/ DC 77-286 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B92075201W
BENDER
IZ427-D59CBW-2
Part number #: B92075201W
insulations Monitoring Device with impedance monitoring Un: AC 47-53Hz 70-300 V Us=Un: AC 47-53 Hz 70-300 V, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93100533
BENDER
PEM533
Part number #: B93100533
Power quality and Energy Un: 3 (N) AC 230 V/400 V 50Hz Stromeingänge (int. Wandler): 5 A Us:DC/ AC 44-440 Hz 95-250 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1