B94043005
BENDER
RCMA420-DM1C-1
Part number #: B94043005
Residual Current Monitor Idn: DC/AC 0-2000Hz 10-500 mA Us: AC 42-460 Hz, 17…72 V / DC 9,6- 94V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048024T
BENDER
IR470LYT-4018
Part number #: B91048024T
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: AC 50-400 Hz 440 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B98080013
BENDER
W35B
Part number #: B98080013
Measuring CT Din= 35 mm for residual current monitoring systems and for insulation fault location system
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B936202
BENDER
ZUE150
Part number #: B936202
Automatic-Restart-Relay Un:AC 60HZ 110V Us=Un: AC 60 Hz 220 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B94053003
BENDER
RCMS460-L-1
Part number #: B94053003
Residual Current Monitor Idn:AC 42..2000HZ 0...30A Us: DC/ AC 42-460 Hz 16-72 V/ DC 9,6-94 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065502W
BENDER
IRDH575B1W-427
Part number #: B91065502W
insulations Monitoring Device Un:3(N)AC/ DC 20-575 V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048024W
BENDER
IR470LYW-4018
Part number #: B91048024W
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: AC 50-400 Hz 440 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065126W
BENDER
IRDH275W-4925
Part number #: B91065126W
insulations Monitoring Device Un: 3(N)AC 0-793V/DC 0-650V Us: DC 10,2-36 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93060001
BENDER
CME420-D-1
Part number #: B93060001
Current Monitor Ian:AC 42...460HZ 0,1...16 A Us: AC 15-460 Hz, 17…72 V / DC 9,6- 94V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91048028
BENDER
IR470LYT-4091
Part number #: B91048028
insulations Monitoring Device Un: AC/ 3(N)AC 0-793 V Us: DC 9,6-84 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065133W
BENDER
isoPV-335+AGH-PV
Part number #: B91065133W
insulations Monitoring Device with AGH-PV3 Un: AC 0-793V/ DC 0-1100V Us: AC 88-264 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065008W
BENDER
IRDH375W-4227
Part number #: B91065008W
insulations Monitoring Device Un:3(N)AC/ DC 0-150 V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93083017
BENDER
SB146-34
Part number #: B93083017
Fault Voltage Monitor Us: DC 10-90 V / AC 50-400 Hz, 10-65 V quick-blow fuse 6 A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B986841
BENDER
9620-1421
Part number #: B986841
120 kOhm Measuring instrument Skala: 90 Grad , I: 0-20 mA
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93082002
BENDER
GM420-D-2
Part number #: B93082002
Loop Monitoring Device Rl: 0,1...100 Ohm Us: DC / AC 15-460 Hz, 70..300 V quick-blow fuse 6 A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B911764
BENDER
WS20 x 30-8000
Part number #: B911764
Measuring CT -rectangular 20 x 30 mm for residual current monitoring systems and for insulation fault location system
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91080019
BENDER
EDS460-DG-2
Part number #: B91080019
insulation Fault Locator Ids: 2...10 mA, Idn: AC 20 mA...2A Us: DC / AC 42…460 Hz, 70..300 V quick-blow fuse 6 A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B94043008
BENDER
RCMA420-DM-2
Part number #: B94043008
Residual Current Monitor Idn: DC/AC 0-2000Hz 10-500 mA Us: DC/ AC 42-460 Hz 70-300 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B95012039
BENDER
SMO482-12
Part number #: B95012039
Signal Converter for MEDICS Systems Us: AC 50 Hz 230 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91064004
BENDER
IR1575PG1-434
Part number #: B91064004
insulations Monitoring Device Un: 3(N)AC/ DC 20-480 V Us: AC 30-420 Hz, 16-72 V, 400V / DC 10,2-84 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B93100557
BENDER
PEM555-455
Part number #: B93100557
Power quality and Energy Un: 3 (N) AC 400 V/690 V 50Hz Stromeingänge (int. Wandler): 5 A Us:DC/ AC 44-440 Hz 95-250 V, quick-blow fuse 6 A, screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065505W
BENDER
IRDH575B1W-4227
Part number #: B91065505W
insulations Monitoring Device Un: 3(N)AC/DC 20-150 V Us: DC 19,2-72 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B911755
BENDER
WS80x160S
Part number #: B911755
Measuring CT (split core) 80 x 160 mm for residual current monitoring systems and for insulation fault location system
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91068144
BENDER
isoPV485-421
Part number #: B91068144
insulations Monitoring Device Un: AC 0-800 V/DC 0-1000 V Us: DC 9,6-84 V quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
up to 5 items.
B91065504
BENDER
IRDH575B1-4235
Part number #: B91065504
insulations Monitoring Device Un: 3(N)AC/DC 20-150 V Us: AC 40-460 Hz, 88-264 V/ DC 77-286 V, quick-blow fuse 6A screw terminal
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: by agreement
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1