CompareProductAvailability / Price

WAGO
855-4001/200-001
855-4001/200-001
Part number #: 855-4001/200-001
Split-core current transformer; Primary rated current: 200 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 0.5; Cable length: 3 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4001/250-000
855-4001/250-000
Part number #: 855-4001/250-000
Split-core current transformer; Primary rated current: 250 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 0.5
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4005/150-101
855-4005/150-101
Part number #: 855-4005/150-101
Split-core current transformer; Primary rated current: 150 A; Secondary rated current: 5 A; Rated power: 1 VA; Accuracy class: 1; Cable length: 0.5 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4005/200-101
855-4005/200-101
Part number #: 855-4005/200-101
Split-core current transformer; Primary rated current: 200 A; Secondary rated current: 5 A; Rated power: 1 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4005/250-100
855-4005/250-100
Part number #: 855-4005/250-100
Split-core current transformer; Primary rated current: 250 A; Secondary rated current: 5 A; Rated power: 1 VA; Accuracy class: 0.5
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-401/250-501
855-401/250-501
Part number #: 855-401/250-501
Plug-in current transformer; Primary rated current: 250 A; Secondary rated current: 1 A; Rated power: 5 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-401/400-501
855-401/400-501
Part number #: 855-401/400-501
Plug-in current transformer; Primary rated current: 400 A; Secondary rated current: 1 A; Rated power: 5 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-401/600-501
855-401/600-501
Part number #: 855-401/600-501
Plug-in current transformer; Primary rated current: 600 A; Secondary rated current: 1 A; Rated power: 10 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/200-209
855-405/200-209
Part number #: 855-405/200-209
Plug-in current transformer; Primary rated current: 200 A; Secondary rated current: 5 A; Rated power: 2.5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/250-209
855-405/250-209
Part number #: 855-405/250-209
Plug-in current transformer; Primary rated current: 250 A; Secondary rated current: 5 A; Rated power: 2.5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/250-501
855-405/250-501
Part number #: 855-405/250-501
Plug-in current transformer; Primary rated current: 250 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/300-509
855-405/300-509
Part number #: 855-405/300-509
Plug-in current transformer; Primary rated current 300 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/400-501
855-405/400-501
Part number #: 855-405/400-501
Plug-in current transformer; Primary rated current: 400 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/400-509
855-405/400-509
Part number #: 855-405/400-509
Plug-in current transformer; Primary rated current: 400 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/500-509
855-405/500-509
Part number #: 855-405/500-509
Plug-in current transformer; Primary rated current: 500 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/600-509
855-405/600-509
Part number #: 855-405/600-509
Plug-in current transformer; Primary rated current: 600 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/750-501
855-405/750-501
Part number #: 855-405/750-501
Plug-in current transformer; Primary rated current 750 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-405/750-509
855-405/750-509
Part number #: 855-405/750-509
Plug-in current transformer; Primary rated current 750 A; Secondary rated current: 5 A; Rated power: 5 VA; Accuracy class: 0.5; for billing purposes
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4101/200-001
855-4101/200-001
Part number #: 855-4101/200-001
Split-core current transformer; Primary rated current: 200 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 1; Cable length: 3 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4101/250-001
855-4101/250-001
Part number #: 855-4101/250-001
Split-core current transformer; Primary rated current: 250 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 1; Cable length: 3 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4101/300-001
855-4101/300-001
Part number #: 855-4101/300-001
Split-core current transformer; Primary rated current 300 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4101/400-001
855-4101/400-001
Part number #: 855-4101/400-001
Split-core current transformer; Primary rated current: 400 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 1; Cable length: 3 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4101/500-000
855-4101/500-000
Part number #: 855-4101/500-000
Split-core current transformer; Primary rated current: 500 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 0.5
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4105/250-101
855-4105/250-101
Part number #: 855-4105/250-101
Split-core current transformer; Primary rated current: 250 A; Secondary rated current: 5 A; Rated power: 1 VA; Accuracy class: 1; Cable length: 0.5 m
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology

WAGO
855-4105/300-101
855-4105/300-101
Part number #: 855-4105/300-101
Split-core current transformer; Primary rated current 300 A; Secondary rated current: 5 A; Rated power: 1 VA; Accuracy class: 1
Price: Please send request
Request Lead Time: app. 1 Day
Delivery Time: app. 2-4 Weeks
Estimated delivery time to our warehouse in Berlin
Delivery Terms: FCA Berlin
individually for each client according to INCOM TERMS 2025
Multiples Of: 1
- Interface Electronic
- Energy Measurement Technology